Page 1 of 12
L-48
M4Y/M4W/M5W/M4M Series
▣ Panel meter selection II
※This panel meter selection is except MT4N / MT4Y / MT4W Series.
Digital panel meter
96
72
96
72
72
48
36
48
41
/2 Digit 31
/2 Digit
Indicator
M5W Series
M4Y Series
M4W Series
M4M Series
M4W1P Series
M4M1P Series
M4W2P Series
M4M2P Series
Power factor
(M4W-P) Scaling rpm
speed Power DC Current
AC Current
DC Voltage
AC Current
L-52 L-54 L-56 L-57 L-58 L-59
Page
Measurement
Series
Output
Size
Display digit
Single output setting Dual output setting
Page 2 of 12
L-49
(A)
Photo
electric
sensor
(B)
Fiber
optic
sensor
(C)
Door/Area
sensor
(D)
Proximity
sensor
(E)
Pressure
sensor
(F)
Rotary
encoder
(G)
Connector/
Socket
(H)
Temp.
controller
(I)
SSR/
Power
controller
(J)
Counter
(K)
Timer
(L)
Panel
meter
(M)
Tacho/
Speed/ Pulse
meter
(N)
Display
unit
(O)
Sensor
controller
(P)
Switching
mode power
supply
(Q)
Stepper
motor&
Driver&Controller
(R)
Graphic/
Logic
panel
(S)
Field
network
device
(T)
Software
(U)
Other
Digital Panel Meter
Specifications
※"★" symbol in power supply is optional. (customizable)
※Environment resistance is rated at no freezing or condensation.
Classification Indicator Single preset output type Dual preset output type Measurement
DC, AC
voltage
M4Y-DV- M4Y-AV -
M5W-DV- M5W-AV- M4W-DV- M4W-AV -
M4M-DV- M4M-AV -
M4W1P-DV- M4W1P-AV -
M4M1P-DV- M4M1P AV -
M4W2P-DV- M4W2P-AV -
M4M2P-DV- M4M2P-AV -
DC, AC
ampere
M4Y-DA- M4Y-AA -
M5W-DA- M5W-AA -
M4W-DA- M4W-AA -
M4M-DA- M4M-AA -
M4W1P-DA- M4W1P-AA -
M4M1P-DA- M4M1P-AA -
M4W2P-DA- M4W2P-AA -
M4M2P-DA- M4M2P-AA -
AC power
(0-10VDC)
M4Y-W- ☐
M5W-W- ☐
M4W-W- ☐
M4M-W- ☐
M4W1P-W- M4M1P-W- M4W2P-W
M4M2P-W
rpm, speed
(0-10VDC)
(0-10VAC)
M4Y-T ☐- ☐
M4Y-S ☐- ☐
M5W-T- ☐
M5W-S- ☐
M4W-T ☐- ☐
M4W-S ☐- ☐
M4M-T- ☐
M4M-S- ☐
M4W1P-T -
M4W1P-S -
M4M1P-T- M4M1P-S- M4W2P-T -
M4W2P-S -
M4M2P-T- M4M2P-S- Power factor
(DC4-20mA) - M4W-P
(Refer to L-57) - -
Max. allowable input 150% for each input specification(At 400VAC:120%)
Power supply
100-240VAC 50/60Hz
★ 5VDC
(Except for M5W)
★ 24-70VDC
110/220VAC 50/60Hz
★ 24-70VDC
★ 100-240VAC 50/60Hz
Allowable voltage range 90 to 110% of rated voltage
Power consumption DC: 2W, AC: 4VA DC: 3W, AC: 5VA
Display method 7 Segment LED display
Character height M4Y, M4W, M5W : 14mm / M4W1P, M4W2P, M4M1P, M4M2P : 10mm
Display accuracy DC : F.S. ±0.2% rdg ±1digit
AC : F.S. ±0.5% rdg ±1digit
Sampling period 300ms
A/D conversion method Dual slope integral method
Response time 2sec.(0 to Max.)
Display frequency 2.5 times/sec.
Contact capacity - Relay contact output :
250VAC 3A 1c
Relay contact output :
250VAC 3A 1c×2
Insulation resistance 100MΩ(at 500VDC megger)
Dielectric strength 2000VAC 50/60Hz for 1 minute
Noise strength ±1kV the square wave noise (pulse width: 1us) by the noise simulator
Vibration
Mechanical 0.75mm amplitude at frequency of 10 to 55Hz(for 1 min.) in each of X, Y, Z directions for 1 hour
Malfunction 0.5mm amplitude at frequency of 10 to 55Hz(for 1 min.) in each of X, Y, Z directions for 10 minutes
Shock
Mechanical 300m/s2(approx. 30G) in X, Y, Z directions for 3 times
Malfunction 100m/s2(approx. 10G) in X, Y, Z directions for 3 times
Relay
life cycle
Mechanical - Min. 10,000,000 operations
Malfunction - Min. 100,000 operations (250VAC 3A resistive load)
Environ- ment
Ambient temperature -10 to 50°C, storage: -20 to 60°C
Ambient humidity 35 to 85%RH, storage: 35 to 85%RH
Unit weight M4Y: Approx. 144g
M5W: Approx. 172g
M4W: Approx. 168g
M4M: Approx. 262g
(M4M-P: Approx. 268g)
M4W1P: Approx. 253g
M4M1P: Approx. 290g
M4W2P: Approx. 278g
M4M2P: Approx. 316g
Page 3 of 12
L-50
M4Y/M4W/M5W/M4M Series
Dimensions
(unit: mm)
(unit: mm)
(unit: mm)
85
98
86
13 113
67
Min. 91
Min. 91
72
Min. 116
96
48
45
Min. 52
12 104
93
Min. 91
72 7 36
30
Min. 40
67 + 0.7
0
● M4Y
● M4W
● M4M ● M4M1P ● M4M2P
● M4W1P ● M4W2P ● M5W
● Panel cut-out
● Panel cut-out
● Panel cut-out
※Unit will be displayed in of front panel.
※Unit will be displayed in of front panel.
※Unit will be displayed in of front panel.
92
45 31+ 0.5
0
+ 0.8
0
+ 0.6
0
68+ 0.7
0
68+ 0.7
0
Page 4 of 12
L-51
(A)
Photo
electric
sensor
(B)
Fiber
optic
sensor
(C)
Door/Area
sensor
(D)
Proximity
sensor
(E)
Pressure
sensor
(F)
Rotary
encoder
(G)
Connector/
Socket
(H)
Temp.
controller
(I)
SSR/
Power
controller
(J)
Counter
(K)
Timer
(L)
Panel
meter
(M)
Tacho/
Speed/ Pulse
meter
(N)
Display
unit
(O)
Sensor
controller
(P)
Switching
mode power
supply
(Q)
Stepper
motor&
Driver&Controller
(R)
Graphic/
Logic
panel
(S)
Field
network
device
(T)
Software
(U)
Other
Digital Panel Meter
Connections
INPUT
1 2 3 4 5 6
INPUT
INPUT
INPUT
INPUT
LOW OUT HI OUT
HI OUT
N.C. N.O.
COM
HIGH
HI
HI
HI
HI
SOURCE
SOURCE
SOURCE
SOURCE
SOURCE
100-240VAC 50/60Hz
5VDC(Option)
24-70VDC(Option)
100-240VAC 50/60Hz
24-70VDC(Option)
- +
+
+
+
+
+
-
-
-
-
-
- +
-
LOW
LOW
LOW
LOW
LOW
HOLD
1
1
9
1
9
1
10
2
11
3
12
4
13
5
14
6
15
7
16
8
2 3 4 5 6 7 8
10 11 12 13 14 15 16
2
2
3
3
4
4
5
5
6
6
7
7
8
8
● M4Y ● M4M
● M4M1P
● M4M2P
● M4W
● M5W
● M4W1P
● M4W2P
RELAY CONTACT OUT
: 250VAC 3A 1c
RESISTIVE LOAD
RELAY CONTACT
OUT :250VAC 3A 1c
RESISTIVE LOAD
100-240VAC 24-70VDC 50/60Hz 4VA
- +
Power option
DC SMPS
Power
AC SMPS
Power
6
1 2 3
100-240VAC
24-70VDC 2W 50/60Hz 4VA
+ -
Power option
DC SMPS
Power
AC SMPS
Power
1 2 3
100-240VAC
24-70VDC 2W 50/60Hz 5VA
+ -
Power option
DC SMPS
Power
AC SMPS
Power
1 2 3 1 2 3
100-240VAC
24-70VDC 3W 50/60Hz 5VA
+ -
Power option
DC SMPS
Power
AC SMPS
Power
1 2 3 1 2 3
7 8 6 7 8
100-240VAC
50/60Hz 4VA
100-240VAC
50/60Hz 5VA
24-70VDC
- +
Power option
DC SMPS
Power
AC SMPS
Power
6 7 8 6 7 8
24-70VDC
- +
Power option
DC SMPS
Power
AC SMPS
Power
6 7 8 6 7 8
NC NO NC NO
COM COM
INPUT
HI LOW
SOURCE
110VAC
50/60Hz
220VAC
0V 50/60Hz
+
HOLD
8
1
15 17
16 18
9
2
10
3
11
4
12
5
13
6
14
7
INPUT
HI LOW
NO NC
COM
HI SET OUT
: 250VAC 3A 1c
RESISTIVE LOAD
SOURCE
110VAC
50/60Hz
220VAC
0V 50/60Hz
+ -
HOLD
8
1
15 17
16 18
9
2
10
3
11
4
12
5
13
6
14
7
INPUT
HI LOW
NO
NO
NC
COM NC
COM
HI SET OUT
: 250VAC 3A 1c
RESISTIVE LOAD
LOW SET OUT
: 250VAC 3A 1c
RESISTIVE LOAD
SOURCE
110VAC
50/60Hz
220VAC
0V 50/60Hz
+ -
HOLD
8
1
15 17
16 18
9
2
10
3
11
4
12
5
13 14
7
HOLD 220VAC
50/60Hz
110VAC
50/60Hz 0V
HOLD 220VAC
50/60Hz
110VAC
50/60Hz 0V
HOLD 220VAC
50/60Hz
110VAC
50/60Hz 0V
Page 5 of 12
L-52
M4Y/M4W/M5W/M4M Series
Features
Ordering information
※1: Measuring input and display are 1:1.
※2: Available input can be direct connection if under 300VDC, 400VAC.
※3: M5W AC measurement type has RMS only. It does not have "R" in model name.
※4: M4Y, M5W are indicator.
DIN W72×H36mm, W96×H48mm, W72×H72mm
Digital panel meter for measuring voltage
● Max. display: 19999(M5W), 1999(Others)
● Auto zero function or Hold function(Except for M5W)
● RMS/AVG value selection function(AC Voltage)
● 7 Segment LED Display
● Case size by DIN specification
● Indicator, Single preset output type,
Dual preset output type
Item
Digit
Size
Output
Input
AC measuring
method
Measuring
input※1
M 4 W AV 1
NO
M4Y / M4W / M4M M5W
DC INPUT
(F.S.)
AC INPUT
(F.S.)
DC INPUT
(F.S.)
AC INPUT
(F.S.)
1 199.9mV 199.9mV 199.99mV 199.99mV
2 1.999V 1.999V 1.9999V 1.9999V
3 19.99V 19.99V 19.999V 19.999V
4 199.9V 199.9V 199.99V 199.99V
5※2 300V - 300.0V 400.0V
6※2 - 400V - -
XX Option Option
No mark AVG value
R※3 RMS value
DV DC Volt
DA DC Ampere
AV AC Volt
AA AC Ampere
No mark Indicator
1P Single setting
2P Dual setting
Y※4 DIN W72×H36mm
W※4 DIN W96×H48mm
M DIN W72×H72mm
4 1999(31⁄2digit)
5 19999(41⁄2digit)
M Meter
Please read “Caution for your safety” in operation
manual before using.
Page 6 of 12
L-53
(A)
Photo
electric
sensor
(B)
Fiber
optic
sensor
(C)
Door/Area
sensor
(D)
Proximity
sensor
(E)
Pressure
sensor
(F)
Rotary
encoder
(G)
Connector/
Socket
(H)
Temp.
controller
(I)
SSR/
Power
controller
(J)
Counter
(K)
Timer
(L)
Panel
meter
(M)
Tacho/
Speed/ Pulse
meter
(N)
Display
unit
(O)
Sensor
controller
(P)
Switching
mode power
supply
(Q)
Stepper
motor&
Driver&Controller
(R)
Graphic/
Logic
panel
(S)
Field
network
device
(T)
Software
(U)
Other
Digital Panel Meter
(Fig. 2) Measuring higher than 300VDC of measurement
voltage
(Fig. 3) Measuring lower than 400VAC of measurement
voltage (V1)
(Fig. 4) Measuring higher than 400VAC of measurement
voltage (V1)
(Fig. 1) Measuring lower than 300VDC of measurement
voltage (V1)
V3 = R2 × V1 R1 > R2 R1 + R2
V2 = N2 × V1 N1
Load
Load
V1
V1 V2
Multiplier
Power supply
Power supply
Low
Low
Hi
Hi
R1
R2
D.P.M
D.P.M
Load
Load
V1
V1 V2
Power supply
Power supply
Low
Low
Hi
Hi
P.T
N1 N2
D.P.M
D.P.M
The application of connections
Measuring DC voltage
※When measuring voltage is higher than 300VDC, please
select R1 and R2 with multiplying resistance on the ex- ternal to make V2 less than max. measurement voltage.
※When measuring voltage is higher than 400VAC, please
use the P.T on the external. (V2 voltage must be lower
than max. measurement voltage)
Ex)Ordering D.P.M for measuring 1000VAC
Select the P.T having 1000VAC of 1st part voltage and
220VAC of 2nd part voltage and order the D.P.M indi- cating 1000V for 220VAC.
Ex)Ordering D.P.M for measuring 1000VDC
As above Fig. 2, select the R1 value to make 300VDC
on R2.
(Generally R1 value will be higher than R2 value.)
Order the D.P.M indicating 1000V for 300VDC.
Measuring AC voltage
Proper usage
● Please notice the product customized by requirement
cannot be replaced.
● If it displays arbitrary number even though the power is
ON, please remove the input signal and check whether
it displays "000" after short the measurement terminal.
(Checking auto zero function)
If it does not display "000", please connect to our A/S
center.
Note)M5W Series does not have auto zero function.
● If it indicates "1999" or "`999" during input signal is ON,
please turn OFF the power and check the connection
condition.
It is because the input signal is too low or high. Note)
M5W Series indicates "19999" or "`9999".
● The specification of measurement input, which
is indicated in ordering information, is a standard
specification, 1:1 of measurement input and process
value. When it is an optional specification of AC voltmeter,
please mark the specification of P.T after select a model.
※Please notice P.T is not included.
● The D.P.M for measuring AC voltage has both AVG type
and RMS type separately. Because it is produced with
AVG type, please mark the model name accurately.
Ex)In case of M4Y, M4W, M4M Series (Include setting
type)
The model of RMS type: M4W-AVR-6
The model of AVG type: M4W-AV-6
※The specification will be set by sign "R".
※M5W Series has RMS type only, and it is not
indicated "R" on the model name.
● In case of D.P.M for measuring AC voltage, please check
if it is AVG type or RMS type when comparison measuring
with other company's products.
Page 7 of 12
L-54
M4Y/M4W/M5W/M4M Series
Features
Ordering information
DIN W72×H36mm, W96×H48mm, W72×H72mm
Digital panel meter for measuring ampere
● Max. display: 19999(M5W), 1999(Others)
● Auto zero function or hold function(Except for M5W)
● RMS/AVG value selection function(AC Voltage)
● 7 Segment LED display
● Case size by DIN specification
● Indicator, single preset output type,
Dual preset output type
※1: Measuring input and display is 1:1 for DC INPUT No.1to 5 and AC INPUT No.1 to 3, DC INPUT No.6 to 8 is
used with DC50mV Shunt, AC INPUT No.4 to 6 are used with C.T(Current transformer)
※2: M5W AC measurement type has RMS only. It does not have "R" in model name.
※3: M4Y, M5W are indicator.
Item
Digit
Size
Output
Input
AC measuring
method
Measuring
input※1
M 4 W AA 1
NO
M4Y / M4W / M4M M5W
DC INPUT
(F.S.)
AC INPUT
(F.S.)
DC INPUT
(F.S.)
AC INPUT
(F.S.)
1 199.9μA 19.99mA 199.99μA 19.999mA
2 1.999mA 199.9mA 1.9999mA 199.99mA
3 19.99mA 1.999A 19.999mA 1.9999A
4 199.9mA 19.99A 199.99mA 19.999A
5 1.999A 199.9A 1.9999A 199.99A
6 19.99A 1999A 19.999A 1999.9A
7 199.9A - 199.99A -
8 1999A - 1999.9A -
XX Option Option
No mark AVG value
R※2 RMS value
DV DC Volt
DA DC Ampere
AV AC Volt
AA AC Ampere
No mark Indicator
1P Single setting
2P Dual setting
Y※3 DIN W72×H36mm
W※3 DIN W96×H48mm
M DIN W72×H72mm
4 1999(31⁄2digit)
5 19999(41⁄2digit)
M Meter
Please read “Caution for your safety” in operation
manual before using.
Page 8 of 12
L-55
(A)
Photo
electric
sensor
(B)
Fiber
optic
sensor
(C)
Door/Area
sensor
(D)
Proximity
sensor
(E)
Pressure
sensor
(F)
Rotary
encoder
(G)
Connector/
Socket
(H)
Temp.
controller
(I)
SSR/
Power
controller
(J)
Counter
(K)
Timer
(L)
Panel
meter
(M)
Tacho/
Speed/ Pulse
meter
(N)
Display
unit
(O)
Sensor
controller
(P)
Switching
mode power
supply
(Q)
Stepper
motor&
Driver&Controller
(R)
Graphic/
Logic
panel
(S)
Field
network
device
(T)
Software
(U)
Other
Digital Panel Meter
(Fig. 2) Measuring higher than DC2A of current
(Fig. 3) Measuring lower than AC5A of current
(Fig. 4) Measuring higher than AC5A of current
(Fig. 1) Measuring lower than DC2A of current
D.P.M
D.P.M
D.P.M
D.P.M
Power supply
Power supply
Power supply
C.T Power supply
Low
Low
Low
Low
Hi
Hi
Hi
Hi
Load
Load
Shunt
Load
Load
DC50mV
+
-
+
-
V
V
I
I
I
I
Connections
Measuring DC ampere
※Higher than DC2A is using shunt for measuring current.
※Basically the 2nd part of shunt value is DC50mV.
Ex) Ordering D.P.M in case of DC10A of measuring ampere:
Select DC10A/50mVDC of shunt and 50mVDC/DC10.00A
of D.P.M.
Measuring AC ampere
Ex) Ordering D.P.M in case of lower than AC5A of
measuring ampere : Select M4W-AA-XX AC5A/5.00A
※If the current is higher than AC5A, please use C.T.
Ex) How to order D.P.M in case of AC300A of measuring
ampere : Select AC300A/5A of C.T and AC5A/300A of
D.P.M.
Proper usage
● Please notice the product customized by requirement
cannot be replaced.
● If it displays arbitrary number even though the power is
ON, please remove the input signal and check whether
it displays "000"after short the measurement terminal.
(Checking auto Zero function)
If it does not display "000", please connect to our A/S
center.
Note) M5W Series does not have auto zero function.
● If it indicates "1999" or "`999"during input signal is ON,
please turn OFF the power and check the connection
condition.
It is because the input signal is too low or high.
Note) M5W Series indicates "19999" or "`9999".
● The specification of measurement input, which
is indicated in ordering information, is a standard
specification, 1:1 of measurement input and process
value.
※Please notice a shunt and C.T are not included.
● The D.P.M for measuring AC ampere has both AVG type
and RMS type separately.
Because it is produced with AVG type, please mark the
model name accurately.
Ex) In case of M4Y, M4W, M4M Series(Include setting
type)
The model of RMS type: M4W-AAR-5
The model of AVG type: M4W-AA-5
※The specification will be set by sign "R".
※M5W Series has RMS type only, and it is not
indicated "R" on the model name.
● In case of D.P.M for measuring AC ampere, please
check if it is AVG type or RMS type when comparison
measuring with other company's products.
Page 9 of 12
L-56
M4Y/M4W/M5W/M4M Series
Features
Ordering information
DIN W72×H36mm, W96×H48mm, W72×H72mm
Digital panel meter for measuring power
● Max. display : 19999(M5W), 1999(Others)
● Auto zero function and hold function(Except for M5W)
● Display the output(0-10VDC) from power converter.
(It is available to correspond when output is DC4-
20mA, 1-5VDC.)
● 7 Segment LED display
● Case size by DIN specification.
● Indicator, single preset output type, Dual preset out- put type
Application of connection
※1: When output specification of power converter is 0-10VDC, display value is maximum.
※2: M4Y, M5W are indicator.
※If output specification of Converter or power converter is DC4-20mA or 1-5VDC, please use scaling meter.
● The specification of measuring input indicated
in ordering information, is display value output
specification is 0-10VDC.
● When the output of transducer or converter is
DC4-20mA or 1-5VDC, please use scaling meter.
Item
Digit
Size
Output
Measurement function
Display scale※1
M 4 W W 1
NO
M4Y / M4W / M4M M5W
DISPLAY(F.S.) DISPLAY(F.S.)
1 199.9W 199.99W
2 1.999kW 1.9999kW
3 19.99kW 19.999kW
4 199.9kW 199.99kW
5 1999kW 1999.9kW
XX Option Option
W Watt Meter
No mark Indicator
1P Single setting
2P Dual setting
Y※2 DIN W72×H36mm
W※2 DIN W96×H48mm
M DIN W72×H72mm
4 1999(31⁄2digit)
5 19999(41⁄2digit)
M Meter
L1 L2 L3
P.T
P.T
C.T
Load
D.P.M
(Transducer)
Output : Power supply
DC0-10V
C.T
+
-
Hi
Low
Please read “Caution for your safety” in operation
manual before using.
Page 10 of 12
L-57
(A)
Photo
electric
sensor
(B)
Fiber
optic
sensor
(C)
Door/Area
sensor
(D)
Proximity
sensor
(E)
Pressure
sensor
(F)
Rotary
encoder
(G)
Connector/
Socket
(H)
Temp.
controller
(I)
SSR/
Power
controller
(J)
Counter
(K)
Timer
(L)
Panel
meter
(M)
Tacho/
Speed/ Pulse
meter
(N)
Display
unit
(O)
Sensor
controller
(P)
Switching
mode power
supply
(Q)
Stepper
motor&
Driver&Controller
(R)
Graphic/
Logic
panel
(S)
Field
network
device
(T)
Software
(U)
Other
Digital Panel Meter
Features
Ordering information
DIN W72×H36mm, W96×H48mm, W72×H72mm
Digital panel meter for measuring Revolution/Speed
● Max. display: 19999(M5W), 1999(Others)
● Auto zero function or hold function(Except for M5W)
● RMS/AVG value selection function(AC voltage)
● 7 Segment LED display
● Case size by DIN specification
● Indicator, single preset output type, Dual preset
output type
※1: AC measuring type of M5W only applies to RMS and it is not marked with "R" in the model name.
※2: M4Y, M5W are indicator.
● Tacho Generator(T.G)
This generator makes a voltage in proportion to revolu- tion speed of motor. The D.P.M receives the voltage
and displays the number of revolution and please check
the specification of T.G.
● The specification of measuring input indicated in order- ing information, is display value when output specifica- tion is 0-10VDC and 0-10VAC. Different output specifi- cation of tacho generator is optional.
Application of connection
Motor Tacho Generator Tacho/Speed meter
LOW
HI
D.P.M POWER T.G
M
Item
Digit
Size
Output
Measurement function
AC measuring
method
Measuring input
M 4 W T 1
NO
M4Y / M4W / M4M M5W
INPUT (F.S.) INPUT (F.S.)
1 0-10VDC / 1999 0-10VDC / 1999.9
2 0-10VAC / 1999 0-10VAC / 1999.9
DX DC Input option DC Input option
XX AC Input option AC Input option
No mark AVG value
R※1 RMS value
T Tachometer(rpm)
S Line Speed Meter(m/min)
No mark Indicator
1P Single setting output
2P Dual setting output
4 1999(31⁄2digit)
5 19999(41⁄2digit)
M Meter
Y※2 DIN W72×H36mm
W※2 DIN W96×H48mm
M DIN W72×H72mm
Please read “Caution for your safety” in operation
manual before using.
Page 11 of 12
L-58
M4Y/M4W/M5W/M4M Series
Features
Ordering information
DIN W72×H36mm, W96×H48mm, W72×H72mm
Digital scaling meter
● Max. display : 19999(M5W), 1999(Others)
● 7 Segment LED display
● Case size by DIN specification
● Linear display function by INPUT specification
● Indicator, single preset output type, dual preset output
type
※1: 1-5VDC of measuring input specification is available by option.
It will be a default value if there is no request for order.
※2: M4Y, M5W are indicator.
● The measurement input specification of ordering information, is an output specification of converter and DC4-20mA is the
standard specification. In case, the output of converter is 1-5VDC, it is customizable.
● DC voltmeter can be produced by requirement, in case, it is out of the 1-5VDC output specification.
Application of connection
Item
Digit
Size
Output
Input
Display scale
Output:DC4-20mA
(1-5VDC: Option) Power supply
(Transducer)
(+)
(-)
LOW
HI Temperature Sensor
Pressure Sensor
CONVERTER
D.P.M
M 4 W DI X
No mark Indicator
1P Single setting
2P Dual setting
4 1999(31⁄2digit)
5 19999(41⁄2digit)
M Meter
X Display range(Option)
DI DC4-20mA(1-5VDC : Option※1
)
Y※2 DIN W72×H36mm
W※2 DIN W96×H48mm
M DIN W72×H72mm
Please read “Caution for your safety” in operation
manual before using.
Page 12 of 12
L-59
(A)
Photo
electric
sensor
(B)
Fiber
optic
sensor
(C)
Door/Area
sensor
(D)
Proximity
sensor
(E)
Pressure
sensor
(F)
Rotary
encoder
(G)
Connector/
Socket
(H)
Temp.
controller
(I)
SSR/
Power
controller
(J)
Counter
(K)
Timer
(L)
Panel
meter
(M)
Tacho/
Speed/ Pulse
meter
(N)
Display
unit
(O)
Sensor
controller
(P)
Switching
mode power
supply
(Q)
Stepper
motor&
Driver&Controller
(R)
Graphic/
Logic
panel
(S)
Field
network
device
(T)
Software
(U)
Other
Digital Panel Meter
Features
Ordering information
DIN W96×H48mm, Digital panel meter for displaying power factor
● Display indicator of power factor
● Input : DC4-20mA(Output specification of
power factor transducer)
● Display : -0.50 to 1.00 to +0.50
Application of connection
Connections Specifications
Dimension
Model M4W-P
Measurement function Power factor
Input DC4-20mA
Display -0.50 to 1.00 to +0.50 cosø
Power supply 110/220VAC 50/60Hz
Allowable voltage range 90 to 110% of rated voltage
Power consumption 4VA
Display method 7 Segment LED display
Character height 14mm
Display accuracy F.S: ±3% rdg ±1digit
Sampling period 300ms
Response speed 2sec.(0 to Max.)
Point display Fixed point
Insulation resistance Min. 100MΩ(at 500VDC megger)
Dielectric strength 2000VAC 50/60Hz for 1 minute
Noise strength ±1kV the square wave noise(pulse width : 1μs)
by the noise simulator
Vibration
Mechanical 0.75mm amplitude at frequency of 10 to 55Hz
(for 1 min.) in each of X, Y, Z directions for 1 hour
Malfunction 0.5mm amplitude at frequency of 10 to 55Hz
(for 1 min.) in each of X, Y, Z directions for 10 minutes
Shock
Mechanical 300m/s2(approx. 30G) in each of X, Y, Z directions for 3 times
Malfunction 100m/s2(approx. 10G) in each of X, Y, Z directions for 3 times
Environ
-ment
Ambient
temperature -10 to 50°C, storage : -25 to 60°C
Ambient humidity 35 to 85%RH, storage : 35 to 85%RH
Unit weight Approx. 317g
● Panel cut-out
(unit: mm)
Item
Digit
Size
Measurement function
M 4 W P
P Power Factor
W DIN W96×H48mm
4 9999(4digit)
M Meter
INPUT
1 2 3 4 5 6 7 8
SOURCE
220VAC
50/60Hz
110VAC
50/60Hz 0V
HI LOW
+ -
L1
Min. 116
96 104
98
12
48
45
Min. 52
L2 L3
P.T
P.T
C.T
LOAD
DPM
(Power factor
transducer)
Power
supply
Output :
DC4-20mA C.T
+
-
Hi
Low
45+ 0.6 0
※Environment resistance is rated at no freezing or condensation.
Please read “Caution for your safety” in operation
manual before using.
92+0.8
0