Page 1 of 15

CLASSIC Series | TRICOR Coriolis Mass Flow Meters

www.tricorflow.com

The TCM CLASSIC product line meets general industrial requirements out of the box.

• TCE 8000 transmitters with an easy-to-use interface

• Economically-priced, non-calibrated but with excellent repeatability

• Optional custom-calibrated meters with high performance specifications

TECHNICAL DATASHEET

Page 2 of 15

2

CLASSIC Series | TRICOR Coriolis Mass Flow Meters TRICOR Coriolis Mass Flow Meters | CLASSIC Series

3

Description, Principle of operation ............................................... 02

Product Overview ........................................................................... 03

TCM Sensor – Technical Data for Liquids ...................................... 04

Accuracy for Liquids ...................................................................... 05

TCM Sensor – Technical Data for Gases......................................... 06

Accuracy for Gases ........................................................................ 07

TCE 8000/8100 Transmitter – Technical Data ................................ 08

TCE 6000 Transmitter – Technical Data ......................................... 09

TRD 8001 Remote Display - Technical Data .................................. 09

Dimensional Drawings................................................................... 10

Ordering Code TCM Meter (TRICOR CLASSIC Series) ..................... 17

Ordering Code TCE Transmitter (Series 8XXX) ............................... 07

Process Connections...................................................................... 19

TRICOR Connection Cable (TCC) for Panel-Mounted Housing ....... 25

Additional Accessories................................................................... 25

Contact ..........................................................................................26

CONTENT

Our passion is

your Process

Page 3 of 15

4

CLASSIC Series | TRICOR Coriolis Mass Flow Meters TRICOR Coriolis Mass Flow Meters | CLASSIC Series

5

PRODUCT OVERVIEW

Compact version

Exd housing: Wall mounted (remote version)

Housing: Panel mounted

(remote version) Version with TCE 6000 (including options)

DESCRIPTION

The TRICOR Coriolis Mass Flow Meters from TASI Flow are absolutely reliable and robust sensors in a variety of processes, performing

multiple measurements simultaneously with customizable process parameters and multiple communication languages. The TRICOR pro- duction team mechanically balances every meter, assuring the dual tubes are dynamically aligned and in perfect balance before flow be- gins. The unique design and cutting edge manufacturing procedures ensure a meter with the highest resistance to external influences.

FEATURES

• All-in-one instrument: direct measurement of mass flow,

density and temperature, calculated measurement of

volumetric flow

• No moving parts: low maintenance, no need for

recalibration

• Easy to install: no straight run of pipe required and multiple

mounting options available

• Mechanically balanced tubes and superior mechanical

design for best-in-class density measurement

• Exceptional mechanical design resists external interference

• API gravity reading in software

• Exceptional ease of use and fast setup time: we will pre- program your process parameters

• Frequency output up to 10,000 Hz resolution

• Superior meter calibration: DAkkS-Accreditation as per

DIN EN ISO/IEC 17025:2005

• Easily accessible, integrated meter diagnostics to verify

meter health & performance

• Hazardous area certifications:

ATEX, IECEx, cCSAus, EAC (TR-CU)

• Customized process connections available

ADDITIONAL OPTIONS

• Net Oil software

• High pressure designs available up to 345 bar [5,000 psi]

• Special calibrations for an oil viscosity up to 100 mm2

/s

• Integrated pressure compensation

• Customizable installation length

• Extended warranty

Coriolis Mass Flow Meters (TCM) operate with two parallel tubes with

coils that cause them to oscillate at their resonance frequency. Should

a measurement flow enter the measuring tube, Coriolis forces are

the result. Coriolis forces appear in oscillating systems when a mass

moves towards or away from a rotational axis. These forces act on the

inlet and outlet side in the opposite direction and minimally deform

the measuring tubes. The deflection of the measurement tubes is

captured by sensors on the inflow and outflow side. These two sensors

measure a phase shift that is proportional to the mass flow. The reso- nance frequency of the tubes varies depending on the density of the

medium to be measured. This effect is used to measure the density of

the medium. Since the elastic properties of the flow tubes depend on

the temperature, a temperature measurement is carried out for com- pensation. The primary characteristics such as mass flow rate, density

and temperature are measured with a single flow meter. The volume

flow can be determined based on the mass flow rate and density.

PRINCIPLE OF OPERATION

∆ T

phase shift = mass flow

t

Page 4 of 15

6

CLASSIC Series | TRICOR Coriolis Mass Flow Meters TRICOR Coriolis Mass Flow Meters | CLASSIC Series

7

TCM

0325

TCM

0650

TCM

1550

TCM

3100

TCM

5500

TCM

7900

TCM

028K

TCM

065K

TCM

230K

Max. Flow Rate (kg/h) 325 650 1,550 3,100 5,500 7,900 28,000 65,000 230,000

Max. Flow Rate (lb/min) 12 24 57 114 202 290 1,029 2,388 8,450

Basic Accuracy (Mass Flow) ±0.3 % of flow rate (option: 0.1 % of flow rate)

Basic Accuracy (Volume Flow) ±0.4 % of flow rate (option: 0.15 % of flow rate)

Repeatability ±0.05 % of flow rate

Zero Stability ±0.01 % of full scale

Density Range up to 2,500 kg/m3 [2.5 g/cm3

] (higher ranges on request)

Density Accuracy ±5.0 kg/m3 [±0.005 g/cm3

] (option: ±1.0 kg/m3 [±0.001 g/cm3

])

Density Repeatability ±0.5 kg/m3

[±0.0005 g/cm3

]

Process Temperature Range ±1 °C ±0.5 % of reading [±1.8 °F ±0.5 % of reading]

Temperature Repeatability ±0.2 °C [±0.36 °F]

Process and Ambient

Process Connections female thread 1/2“

adaptors for flanges, dairy and tri-clamp

flanges EN1092, ANSI B16.5, DIN2512,

threaded tri-clamp

Max. Pressure Standard 200 bar [2,900 psi]

option: 345 bar [5,000 psi] (not forASME) 100 bar [1,450 psi]

Pressure Drop at max. Flow for detail information please contact us

Process Temperature (non Ex) -40 °C ... +100 °C [-40 °F ... +212 °F] (standard)

-40 °C ... +150 °C [-40 °F ... +302 °F] (option)

-60 °C ... +200 °C [-76 °F ... +392 °F] (option)

Process Temperature (Ex) meter mount -40 °C ... +70 °C [-40 °F ... +158 °F] (T4) n/a

remote version -40 °C ... +70 °C [-40 °F ... +158 °F] (T4)

-40 °C ... +135 °C [-40 °F ... +275 °F] (T3)

-60 °C ... +200 °C [-76 °F ... +392 °F] (T2)

Ambient Temperature -40 °C ... +70 °C [-40 °F ... +158 °F]

Storage Temperature -40 °C ... +100 °C [-40 °F ... +212 °F]

Electr. Connections Remote screw type terminals

Electr. Connections Meter Mount none (internally connected to the electronics)

Ingress Protection IP65 (IP66/IP67 on request)

General

Tube Arrangement 2

seriell

2

parallel

2

seriell

2

parallel

2

parallel

2

parallel

2

parallel

2

parallel

2

parallel

Tube Inner Diameter 4 mm 4 mm 8 mm 8 mm 7 mm 9 mm 16 mm 28 mm 43 mm

Tube Material 1.4404 [AISI 316L]

Housing Material 1.4404 [AISI 316L]

Dimensions see dimensional drawings (page 10 - 11)

TCM SENSOR – TECHNICAL DATA FOR LIQUIDS

Calibration for Liquids and Gases: The TRICOR flowmeters are always factory calibrated with water.

Calibration Conditions: Water: 20 °C ... 25 °C [68 °F ... 77 °F], ambient temperature: 20 °C ... 25 °C [68 °F ... 77 °F].

All specifications are based on above mentioned calibration reference conditions, a flow calibration protocol is attached to each instrument.

Stated accuracy combines the effects of repeatability, linearity and hysteresis.

Typical flow dynamics based on max. flow rate is 100:1.

ACCURACY FOR LIQUIDS

Example for a standard TCM 0325

(Single-Point Calibration, Basic Accuracy: ±0.3 %)

325 kg/h * Zero Point (0.01 %) = 0.0325 kg/h

[12 lb/min * 0.01 % = 0.0012 lb/min]

325 kg/h * Basic Accuracy (0.3 %) = 0.975 kg/h

[12 lb/min * 0.3 % = 0.036 lb/min]

Result:

(0.0325 / 0.975) * 100 = 3.33 % (10.8 kg/h)

[(0.0012 / 0.036) * 100 = 3.33 % (0.4 lb/min)]

All Flow Rates ≥ 3.33 % or 10.8 kg/h (0.4 lb/min):

Measured Error = Basic Accuracy

All Flow Rates < 3.33 % or 10.8 kg/h (0.4 lb/min):

Measured Error = (Zero Point / Measured Value) * 100

Flow Rate of Full Scale Accuracy

± Basic Accuracy

±

Zero Point

Measured Value * 100

Zero Point

Basic Accuracy * 100

< Zero Point

Basic Accuracy * 100

Standard

(Single-Point Calibration, Basic Accuracy: ±0.3 %)

Custom

(Five-Point-Calibration, Basic Accuracy: ±0.1 %)

Example for a custom TCM 0325

(Five-Point Calibration, Basic Accuracy: ±0.1 %)

325 kg/h * ZeroPoint (0.01 %) = 0.0325 kg/h

[12 lb/min * 0.01 % = 0.0012 lb/min]

325 kg/h * Basic Accuracy (0.1 %) = 0.325 kg/h

[12 lb/min * 0.1 % = 0.012 lb/min]

Result:

(0.0325 / 0.325) * 100 = 10 % (32.5 kg/h)

[(0.0012 / 0.012) * 100 = 10 % (1.2 lb/min)]

All flow rates ≥ 10 % or 32.5 kg/h (1.2 lb/min):

Measured error = Basic Accuracy

All flow rates < 10 % or 32.5 kg/h (1.2 lb/min):

Measured error = (Zero Point / Measured Value) * 100

Page 5 of 15

8

CLASSIC Series | TRICOR Coriolis Mass Flow Meters TRICOR Coriolis Mass Flow Meters | CLASSIC Series

9

TCM SENSOR – TECHNICAL DATA FOR GASES

TCM

0325

TCM

0650

TCM

1550

TCM

3100

TCM

5500

TCM

7900

TCM

028K

TCM

065K

TCM

230K

Nom. Flow Rate (kg/h)1) 3) 78 177 333 740 910 1,430 5,100 15,650 48,900

Nom. Flow Rate (lb/min)1) 3) 3 7 12 27 34 53 188 575 1,797

Nom. Flow Rate (Nm3

/h)1) 2) 109 247 464 1,031 1,268 1,993 7,109 21,813 68,157

Nom. Flow Rate (SCFM)1) 2) 64 146 273 607 747 1,173 4,184 12,838 40,115

Basic Accuracy ±1 % of flow rate (option: ±0.5 % of flow rate)

Repeatability ±0,25 % of flow rate

Zero Stability (kg/h) 0.0325 0.065 0.155 0.31 0.55 0.79 2.8 6.5 23

Zero Stability (lb/min) 0.0012 0.0024 0.0057 0.0114 0.020 0.029 0.103 0.239 0.845

Density Range see comment3)

Density Accuracy ±5.0 kg/m3

[±0.005 g/cm3

] (option: ±1.0 kg/m3

[±0.001 g/cm3

]

Density Repeatability ±0.5 kg/m3

[±0.0005 g/cm3

]

Process Temperature Range ±1 °C ±0.5 % of reading [±1.8 °F ±0.5 % of reading]

Temperature Repeatability ±0.2 °C [±0.36 °F]

Prozess-/Umgebungsbedingungen

Process Connections female thread 1/2“

adaptors for flanges, dairy and tri-clamp

flanges EN1092, ANSI B16.5, DIN2512,

threaded tri-clamp

Max. Pressure Standard 200 bar [2,900 psi]

option: 345 bar [5,000 psi] (ot for ASME) 100 bar [1,450 psi]

Pressure Drop at max. Flow for detail information please contact us

Process Temperature (non Ex) -40 °C ... +100 °C [-40 °F ... +212 °F] (standard)

-40 °C ... +150 °C [-40 °F ... +302 °F] (option)

-60 °C ... +200 °C [-76 °F ... +392 °F] (option)

Process Temperature (Ex) meter mount -40 °C ... +70 °C [-40 °F ... +158° F] (T4) n/a

remote version -40 °C ... +70 °C [-40 °F ... +158 °F] (T4)

-40 °C ... +135 °C [-40 °F ... +275 °F] (T3)

-60 °C ... +200 °C [-76 °F ... +392 °F] (T2)

Ambient Temperature -40 °C ... +70 °C [-40 °F ... +158 °F]

Storage Temperature -40 °C ... +100 °C [-40 °F ... +212 °F]

Electr. Connections Remote screw type terminals

Electr. Connections Meter Mount none (internally connected to the electronics)

Ingress Protection IP65 (IP66/IP67 on request)

General

Tube Arrangement 2

serial

2

parallel

2

serial

2

parallel

2

parallel

2

parallel

2

parallel

2

parallel

2

parallel

Tube Inner Diameter 4 mm 4 mm 8 mm 8 mm 7 mm 9 mm 16 mm 28 mm 43 mm

Tube Material 1.4404 [AISI 316L]

Housing Material 1.4404 [AISI 316L]

Dimensions see dimensional drawings (page 10 - 11)

Max. allowed flow velocity (Ma 0.5).

For gas applications, flow rate and pressure drop for individual sensor sizes are dependent on operating temperature, pressure and fluid composition.

Therefore, when selecting a sensor for any particular gas application, please use the the TSP (TRICOR Sizing Program) or contact us.

1) Nominal flow rates that produce approximately 3 bar [43 psi] pressure drop for natural gas at 50 bar [725 psi] operational pressure. 2) Normal reference conditions (Nm3

/h) are 1,013 bar und 0 °C. Standard (SCFM) reference conditions are 14.7 psi und 60 °F. 3) Flow rate and density range depend on the gas density and the pressure range.

ACCURACY FOR GASES

4) For Ex1, Ex3, EAC (TR-CU) the electronic is only available in aluminum housing. 5) Only with remote electronics.

EX CERTIFICATIONS

ATEX (Ex) Zone 1: Group IIC or IIB, T2...T4

ATEX (Exn) Zone 2: II 3G Ex nA IIC T2...T4 Gc

IECEx (Ex) Zone 1: Group IIC or IIB, T2...T4

cCSAus (Ex1)4) Class 1, Division 1: Group A, B, C, D or C, D, T2...T4

ATEX + IECEx + cCSAus triple

approval (Ex3)4) 5)

Zone 1: Group IIC or IIB, T2...T4 and

Class 1, Division 1: Group A, B, C, D or C, D, T2...T4

EAC (TR-CU)4) Group IIC or IIB, T2 ... T4

Flow Rate of Full Scale Accuracy

± Basic Accuracy

±

Zero Point

Measured Value * 100

Zero Point

Basic Accuracy * 100

< Zero Point

Basic Accuracy * 100

Standard

(Single-Point Calibration, Basic Accuracy: ±1 %)

Custom

(Five-Point-Calibration, Basic Accuracy: ±0.5 %)

Example for a standard TCM 0325

(Single-Point Calibration, Basic Accuracy: ±1 %)

325 kg/h * Zero Point (0.01 %) = 0.0325 kg/h

[12 lb/min * 0.01 % = 0.0012 lb/min]

325 kg/h * Basic Accuracy (1 %) = 3.25 kg/h

[12 lb/min * 1 % = 0.12 lb/min]

Result:

(0.0325 / 3.25) * 100 = 1 % (3.25 kg/h)

[(0.0012 / 0.12) * 100 = 1 % (0.12 lb/min)]

All Flow Rates ≥ 1 % or 3.25 kg/h (0.12 lb/min):

Measured Error = Basic Accuracy

All Flow Rates < 1 % or 3.25 kg/h (0.12 lb/min):

Measured Error = (Zero Point / Measured Value) * 100

Example for a custom TCM 0325

(Five-Point Calibration, Basic Accuracy: ±0.5 %)

325 kg/h * ZeroPoint (0.01 %)= 0.0325 kg/h

[12 lb/min * 0.01 % = 0.0012 lb/min]

325 kg/h * Basic Accuracy (0.5 %) = 1.625 kg/h

[12 lb/min * 0.5 % = 0.06 lb/min]

Result:

(0.0325 / 1.625) * 100 = 2 % (6.5 kg/h)

[(0.0012 / 0.06) * 100 = 2% (0.24 lb/min)]

All flow rates ≥ 2 % or 6.5 kg/h (0.24 lb/min):

Measured error = Basic Accuracy

All flow rates < 2 % or 6.5 kg/h (0.24 lb/min):

Measured error = (Zero Point / Measured Value) * 100

Page 6 of 15

10

CLASSIC Series | TRICOR Coriolis Mass Flow Meters TRICOR Coriolis Mass Flow Meters | CLASSIC Series

11

TCE 8000/8100 TRANSMITTER – TECHNICAL DATA

General

Display back-lit LCD screen, 132 x 32 dot

Supply Voltage 24 V DC, ±20 % or 90 ... 264 V (version dependent)

Programming via front keyboard or Windows-based TRICOR configurator program (Modbus)

Interface RS485 (Modbus-RTU), option HART®, Foundation Fieldbus® , other options on request

EMV according to EN 61000-6-4 and 61000-6-2

Power Consumption max. 6 W

ExD Housing: Wall-mounted

Dimensions see dimensional drawing (page 12 - 13)

Electrical Connections cage clamp terminals

Cable Glands for 7-13 mm cables

Housing Material aluminum diecast (option: 1.4404 [AISI 316L])

Protection Class IP65 (IP66/IP67 on request)

Weight with aluminum diecast housing: 3.8 kg [8.3 lb] with 3 m cable

with 1.4404 [AISI 316L] housing: 6.15 kg [13.56 lb]

Temperature ambient: -40 °C ... +70 °C [-40 °F ... +158 °F]

storage and transport: -40 °C ... +80 °C [-40 °F ... +176 °F]

Housing: Panel-mounted (only TCE 8000)

Dimensions see dimensional drawing (page 15)

Electrical Connections cage clamp terminals

Housing Material Noryl

Protection Class front: IP50, rear: IP30

Weight 0.4 kg [0.88 lb]

Temperature ambient: ±0 °C ... +60 °C [32 °F ... +140 °F]

storage and transport: -20 °C ... +70 °C [-4 °F ... +158 °F]

Analog Output

Current Outputs (2x) 4 ... 20 mA passive, two-wire, isolated

Resolution 14 bit

Linearity ±0.05 % of full scale

Temperature Drift 0.05 % per 10 K

Load < 620 Ω (at 24 V supply)

Output Value programmable: flow, total, density, temperature

Pulse Output

Frequency Range 0.5 - 10,000 Hz (in TOTAL mode: 0 - 100 Hz)

Output Signal active push pull output for flow rate

Status In- and Output

Status Output push pull programmable

(in FREQUENCY mode: 0.5 - 10,000 Hz)

Control Input programmable

Analog Input (option)

Input Type 4 ... 20 mA active for two-wire passive pressure sensor

Resolution 12 bit

Linearity ±0.05 % of full scale

Temperature Drift 0.05 % per 10 K

Supply Voltage > 20 V (at 20 mA sensor current)

General

Supply Voltage 24 V DC, ±20 %

Programming via TRD 8001 or via interface

Interface RS485, USB (option)

EMC according to EN 61000-6-4 and EN 61000-6-2

Power Consumption max. 4 W

Dimensions see dimensional drawing (page 15)

Electrical Connections connectors M12

Housing Material aluminum diecast

Temperature ambient: : -40 °C ... +70 °C [-40 °F ... +158 °F]

storage and transport: -40 °C ... +80 °C [-40 °F ... +176 °F]

Protection Class IP65

Analog Output

Current Output 4 ... 20 mA active

Resolution 14 bit

Linearity ±0.05 %

Temperature Drift 0.05 % per 10 K

Load < 800 Ω

Output Value programmable: flow, total, density, temperature

Pulse Output

Frequency Range 0.5 - 10,000 Hz (for ESTA (OPTV receiver) 0.5 - 5,000 Hz)

Output Signal active push pull output for flow rate, optional: insulated optical frequency output

Status In- and Output

Status Output push pull programmable (option)

(in TOTAL mode: 0.5 - 100 Hz)

Control Input programmable (standard: 1 input/option: 2 inputs)

option: insulated optical control input

TCE 6000 TRANSMITTER – TECHNICAL DATA

Display back-lit LCD screen, 132 x 32 dot

Supply Voltage via interface

Programming via front keyboard

Interface to TCE RS485

EMC according to EN 61000-6-4 and 61000-6-2

Dimensions see dimensional drawing (page 16)

Electrical Connections connectors M12

Housing Material ABS-FR (plastic, flame retardant)

Protection Class IP64

Weight 0.4 kg [0.88 lb]

Temperature operation: ±0 °C ... +60 °C [32 °F ... +140 °F]

storage and transport: -20 °C ... +80 °C [- 4°F ... +176 °F]

Wall Mount hidden screws

TRD 8001 REMOTE DISPLAY – TECHNICAL DATA

Note: For parameterization of the flow meter, the interface may be used.

Prerequisite: Parameter setting is not allowed during active ESTA operation.

Page 7 of 15

12

CLASSIC Series | TRICOR Coriolis Mass Flow Meters TRICOR Coriolis Mass Flow Meters | CLASSIC Series

13

TCM 0325 TO TCM 0650

L

Y

H

22mm

0.87in G E

60mm

2.36in

70mm

2.76in

D

A

Dokumentennr Dokumentname Datum Name

JJ/MM.NNXX TCM 325_3100 Datenblatt Allgemein-DE Mittwoch, 10. August 2016

09:56:13 griebel

Sensor Type A D E G6) H L7) Y

TCM 0325 214 mm

[8.43 in] M6 10 15 mm

[0.59 in] G 1⁄2“ 182 mm

[7.17 in]

110 mm

[4.33 in]

216 mm

[8.50 in]

TCM 0650 214 mm

[8.43 in] M6 10 15 mm

[0.59 in] G 1⁄2“ 182 mm

[7.17 in]

110 mm

[4.33 in]

216 mm

[8.50 in]

6) Other connections on request. 7) Further lengths on request.

TCM 1550 TO TCM 3100

L

Y

H

A 59mm

2.32in

22mm

0.87in G E D

70mm

2.76in

Dokumentennr Dokumentname Datum Name

16/08.0011 TCM 1550_3100 compact DE Mittwoch, 10. August 2016

10:06:24 griebel

Sensor Type A D E G6) H L7) Y

TCM 1550 350 mm

[13.78 in] M6 10 18 mm

[0.71 in] G 1⁄2“ 280 mm

[11.02 in]

140 mm

[5.51 in]

384 mm

[15.12 in]

TCM 3100 350 mm

[13.78 in] M6 10 18 mm

[0.71 in] G 1⁄2“ 280 mm

[11.02 in]

140 mm

[5.51 in]

384 mm

[15.12 in]

874mm

34.4in

974mm

38.37in

704mm

27.73in

32mm

1.26in

891mm

35.07in

230mm

9.06in

TCM 230K

TCM 5500 TO TCM 065K

Sensor Type B C H L8) I.D. Connection

TCM 5500, 7900 61 mm

[2.40 in]

204 mm

[8.03 in]

260 mm

[10.24 in]

460 mm

[18.11 in]

Ø 13 mm

[Ø 0.51 in] on request

TCM 028K 80 mm

[3.15 in]

253 mm

[9.96 in]

315 mm

[12.40 in]

625 mm

[24.61 in]

Ø 23 mm

[Ø 0.91 in] on request

TCM 065K 151 mm

[5.94 in]

387 mm

[15.24 in]

480 mm

[18.90 in]

830 mm

[32.68 in]

Ø 40 mm

[Ø 1.57 in] on request

L

H

B

C

ID

Dokumentennr Dokumentname Datum Name

16/08.0005 TCM Datenblatt Allgemein-DE_EN Mittwoch, 10. August 2016

08:08:40 griebel

8) Further lengths on request..

Page 8 of 15

14

CLASSIC Series | TRICOR Coriolis Mass Flow Meters TRICOR Coriolis Mass Flow Meters | CLASSIC Series

15

WALL-MOUNT ELECTRONICS TCE 8000/8100

147mm

5.79in

110mm

4.33in 138mm

5.45in

10mm

0.39in

10,50mm

0.41in

203mm

7.99in

116mm

4.57in

118mm

4.65in

147mm

5.79in

110mm

4.33in

68mm

2.68in

203mm

7.99in

118mm

4.65in

166mm

6.52in

METER-MOUNT ELECTRONICS TCE 8000/8100 METER-MOUNT ELECTRONICS TCE 8000/8100 WITH BLIND COVER

147mm

5.79in

110mm

4.33in

68mm

2.68in

184mm

7.24in

166mm

6.52in

99mm

3.90in

Dokumentennr Dokumentname Datum Name

JJ/MM.NNXX TCE 80xx-24 BG-DE Donnerstag, 6. Oktober 2016

13:44:49 griebel

147mm

5.80in

110mm

4.32in

68mm

2.68in

234mm

9.19in

203mm

7.99in

118mm

4.65in

Dokumentennr Dokumentname Datum Name

JJ/MM.NNXX TCE 80xx-XXX BG - HT DE Donnerstag, 29. September

2016 14:50:08 griebel

METER-MOUNT ELECTRONICS TCE 8000/8100 HIGH TEMPERATURE

Page 9 of 15

16

CLASSIC Series | TRICOR Coriolis Mass Flow Meters TRICOR Coriolis Mass Flow Meters | CLASSIC Series

17

STANDARD CONNECTION HEAD (A)

88mm

3.45in

68mm

2.68in

57mm

2.23in

72mm

2.82in

115mm

4.52in

Dokumentennr Dokumentname Datum Name

JJ/MM.NNXX TCE JB ALU Mittwoch, 30. März 2016

09:25:15 griebel

101mm

3.96in

85mm

3.33in 105mm

4.14in

77mm

3.01in

63mm

2.48in

HIGH TEMPERATURE CONNECTION HEAD (H)

PANEL-MOUNTED HOUSING

96mm

3.78in

96mm

3.78in

83mm

3.27in

96mm

3.80in

8mm

0.31in

143mm

5.64in

46mm

1.81in

66mm

2.60in

100mm

3.94in

Dokumentennr Dokumentname Datum Name

TCE 60xx BG_DAT_DE Mittwoch, 2. Mai 2018 12:33:22 griebel

METER-MOUNT ELECTRONICS TCE 6000 (F)

Page 10 of 15

18

CLASSIC Series | TRICOR Coriolis Mass Flow Meters TRICOR Coriolis Mass Flow Meters | CLASSIC Series

19

REMOTE DISPLAY TRD 8001

120mm

4.72in

90mm

3.54in 48mm

1.89in

16mm

0.63in

Dokumentennr Dokumentname Datum Name

16/08.0014 TRD 8001 -DE Mittwoch, 10. August 2016

10:53:26 griebel

ORDERING CODE TCM METER (TRICOR CLASSIC SERIES)

9) For connections not indicated with installation length, please contact manufacturer. 10)For TCM compact version with Ex-protection temperature class T4 only.

11)Ex-protection only available in the option Exn. TCE 6000 electronic is not applicable for TCM 230K.

12)Other interfaces on request.

13)For Ex1, Ex3, EAC (TR-CU) the electronic is only available in aluminum housing.

14)Only with remote electronics.

TCM XXXX - XX - X X X X - X X X X - Ex - XX

Process Connections9)

see page 17 ff XX

Mechanical Options

Medium Temperature Range

-40 °C ... +100 °C [-40 °F ... +212 °F] S

-40 °C ... +150 °C [-40 °F ... +302 °F], Exmax: 135 °C [275 °F] H

-40 °C ... +70 °C [-40 °F ... +158 °F], Ex, compact E

-60 °C ... +200 °C [-76 °F ... +392 °F] T

Pressure Range

With rupture disc max. 4 bar [58 psi] G

Mechanical Design

Standard S

Face to Face Length

Standard (other length on request) S

Electronics Options

Electronics Type

Junction box, 1.4404 [316L] H Z Z S

Meter mount, die cast aluminum housing for 1⁄2” NPT cable glands10) C

Meter mount, die cast aluminum housing for M20x1.5 cable glands10) K

Meter mount, stainless steel housing for 1⁄2” NPT cable glands10) M

Meter mount, stainless steel housing for M20x1.5 cable glands10) O

Meter mount electronics TCE 600011) F

Interface12)

RS485 (Modbus RTU) S

RS485 (Modbus RTU) and HART® A

RS485 (Modbus RTU) + FF (not with Ex) B

FF (Foundation Fieldbus®

) D

RS485 (Modbus RTU) + USB (only TCE 6000) F

Not used Z

Supply Voltage

24 V DC D

90 ... 264 V AC M

Not used Z

Options

Pressure compensation, 4 ... 20 mA input A

8 pin I/O connector (TCE 6000 only) B

Optical I/O (TCE 6000 only) C

No option S

EX-Protection

ATEX + IECEx Zone1: Group IIC or IIB, T2...T4 Ex

ATEX Zone 2: II 3G Ex nA IIC, T2...T4 Gc Exn

cCSAus: Class 1, Division 1: Group A, B, C, D or C, D, T2...T413) Ex1

Ex3

EAC (TR-CU): Group IIC or IIB, T2 ... T413) ExR

Special Options

NOC (Net Oil Computer) 01

9) For connections not indicated with installation length, please contact manufacturer.

10) For TCM compact version with Ex-protection temperature class T4 only.

11) Ex-protection only available in the option Exn. TCE 6000 electronic is not applicable for TCM 230K.

12) Other interfaces on request.

13) For Ex1, Ex3, EAC (TR-CU) the electronic is only available in aluminum housing.

14) Only with remote electronics.

ATEX+IECEx: Zone 1: Group IIC or IIB, T2...T4 and

cCSAus: Class 1, Division 1: Group A, B, C, D or C, D, T2...T413) 14)

Page 11 of 15

20

CLASSIC Series | TRICOR Coriolis Mass Flow Meters TRICOR Coriolis Mass Flow Meters | CLASSIC Series

21

15)Only for TCE 80XX.

16)Other interfaces on request.

17)For Ex1, Ex3, EAC (TR-CU) the electronic is only available in aluminum housing.

ORDERING CODE TCE TRANSMITTER (SERIES 8XXX)

TCE 8 X X X - X - X X X X - XX - XX

Housing material: Aluminum 8 0

Housing material: stainless steel 1.4404 [AISI 316L] 8 1

Electronics for TCM 0325 to TCM 7900 0 1

Electronics for TCM 028K to TCM 065K 1 1

Electronics for TCM 230K 1 2

Housing

Wall mount (housing for 1⁄2” NPT cable glands) W

Wall mount (housing for M20x1.5 cable glands) I

Panel mount15) S

Panel mount, wide, for "Ex", "associated equipment"15) L

Options

Interface16)

RS485 (Modbus RTU) S

R485 (Modbus RTU) + HART® A

Supply Voltage

24 V DC + 90 ... 264 V AC (only housing S+L) B

24 V DC D

90 ... 264 V AC (only housing W, I) M

Electronic Options

Standard S

Pressure compensation, 4 ... 20 mA input A

Cable Length

3 Meters [≈ 10 ft.], Standard (high temperature) S (H)

6 Meters [≈ 20 ft.] (high temperature) B (I)

10 Meters [≈ 33 ft.] (high temperature) C (J)

15 Meters [≈ 49 ft.] (high temperature) D (O)

20 Meters [≈ 65 ft.] (high temperature) E (P)

F

D-SUB Connector, (housing L+S) seperate cable required N

Ex-Protection

ATEX + IECEx Zone1: Group IIC or IIB, T2...T4 Ex

ATEX Zone 2: II3G Ex nA IIC, T2...T4 Gc Exn

cCSAus: Class 1, Division 1: Group A, B, C, D or C, D, T2...T417) Ex1

Ex3

EAC (TR-CU): Group IIC or IIB, T2 ... T417) ExR

Special Options

NOC (Net Oil Computer) 01

15) Only for TCE 80XX.

16) Other interfaces on request.

17) For Ex1, Ex3, EAC (TR-CU) the electronic is only available in aluminum housing.

ATEX+IECEx, Zone 1: Group IIC or IIB, T2...T4 and

cCSAus: Class 1, Div. 1: Group A, B, C, D or C, D, T2...T417)

3 Meters [≈ 10 ft.], offshore cable

(halogen-free, flame propagation test: IEC 60332-1, combustion test: IEC 60754-2)

TCC X X - X X

Cable Connector TCE Connector TCM Devices

Standard cable SUB-D, 9-pin cable end sleeves (8-pol.) TCE 8**1-S- 0 2

TCE 8**1-L- Standard cable SUB-D, 9-pin/ cable end sleeves (8-pol.) TCE 8**1-S- 0 4

Din-Rail mounting TCE 8**1-L- High temperature cable SUB-D, 9-pin cable end sleeves (8-pol.) TCE 8**1-S- 0 9

TCE 8**1-L- High temperature cable SUB-D, 9-pin/ cable end sleeves (8-pol.) TCE 8**1-S- 1 0

Din-Rail mounting TCE 8**1-L- Length

3 meter (Standard) [≈ 10 ft.] 0 3

6 meter [≈ 20 ft.] 0 6

10 meter [≈ 33 ft.] 1 0

15 meter [≈ 49 ft.] 1 5

20 meter [≈ 66 ft.] 2 0

TRICOR CONNECTION CABLE (TCC) FOR PANEL-MOUNTED HOUSING

Cable Specifications/Connections

ADDITIONAL ACCESSORIES

Accessories for TCE 8* electronic Model Code

USB interface cable to RS485, 1.8 m (TRICOR configurator) CON.USB.RS-ISO

IP65 Protection for TCE-80**-L IPS 9-14

IP65 Protection for TCE-80**-S IPS 9-9

Adapter TCE-80**-S and TCE-80**-L for rail mounting HSA 96

Accessories for TCE 6000 electronic Model Code

Remote display for TCE 6000 TRD 8001

Connection cable TRD 8001 to TCE 6000, 2 m TRD-TCE-6-2

Connection cable TRD 8001 to TCE 6000, 5 m TRD-TCE-6-5

USB Cable, USB to mini USB M12, 2 m KAB-USB-TCE

RS485 to USB connector cable 3 m

for TCE 6000; versions FSDS;FFDB, FSDC

KAB-RS485-TCE-ISO

Pneumatic Power Gen. Plug M8, 3 pin, 2.5 m cable

for TCE 6000 Version FSDC; 7.5 W, 24 V DC

TCE 6000-FSDC-SET-PPG

Light pulse emitter and receiver, DIN-rail for TCE 6000 Version FSDC OPTV-02/XO

Fiber optic cable for TCE 6000 Version FSDC for FOP 50/60, 10 m (5.5 mm) LW-LA-10

Service and calibration Model Code

DAkkS-Calibration (ILAC) according to DIN EN ISO/IEC 17025:2005 DAkkS-Kalibrierung

Oxygen cleaning TCM Reinigung Sauerstoff TCM

Inspection certificate 3.1 according to DIN 50 049/EN 10204 3.WKZ-0100

TAG Plate 1.4404 [AISI 316L] TCM-Tag-Plate-1.4404

Page 12 of 15

22

CLASSIC Series | TRICOR Coriolis Mass Flow Meters TRICOR Coriolis Mass Flow Meters | CLASSIC Series

23 19)Connections without installation length are not possible or need manufacturer release. Please contact the manufacturer.

Process connection19) Code TCM

0325

TCM

0650

TCM

1550

TCM

3100

TCM

5500

TCM

7900

TCM

028K

TCM

065K

TCM

230K

2” ANSI flange class 150 AN 625

[24.61]

830

[32.68]

2” ANSI flange class 300 AO 625

[24.61]

830

[32.68]

2” ANSI flange class 600 AP 625

[24.61]

830

[32.68]

2” ANSI flange class 900 AR 625

[24.61]

830

[32.68]

2” ANSI flange class 1500 BU 830

[32.68]

21⁄2” ANSI flange class 150 BT 830

[32.68]

21⁄2” ANSI flange class 300 BY 830

[32.68]

21⁄2” ANSI flange class 600 BQ 830

[32.68]

21⁄2” ANSI flange class 900 BW 830

[32.68]

3” ANSI flange class 150 AS 625

[24.61]

830

[32.68]

915

[36.02]

3” ANSI flange class 300 AT 830

[32.68]

915

[36.02]

3” ANSI flange class 600 AU 830

[32.68]

915

[36.02]

3” ANSI flange class 900 AV 830

[32.68]

915

[36.02]

4” ANSI Flange class 150 AW 830

[32.68]

915

[36.02]

4” ANSI flange class 300 AX 830

[32.68]

915

[36.02]

4” ANSI flange class 600 AY 830

[32.68]

915

[36.02]

4” ANSI flange class 900 AZ 830

[32.68]

915

[36.02]

5” ANSI flange class 150 BF 915

[36.02]

5” ANSI flange class 300 BG 915

[36.02]

5” ANSI flange class 600 BH 915

[36.02]

5” ANSI flange class 900 BJ 915

[36.02]

6” ANSI flange class 150 BM 915

[36.02]

6” ANSI flange class 600 BX 915

[36.02]

SLIP ON, PROCESS CONNECTION DIM. + FACING ACC. ANSI B16.5

INSTALLATION LENGTH IN MM [INCH]

18) Connections without installation length are not possible or need manufacturer release. Please contact the manufacturer.

Process connection18) Code TCM

0325

TCM

0650

TCM

1550

TCM

3100

TCM

5500

TCM

7900

TCM

028K

TCM

065K

TCM

230K

1⁄2” ANSI flange class 150 AA 390

[15.35]

390

[15.35]

420

[16.54]

420

[16.54]

460

[18.11]

460

[18.11]

1⁄2” ANSI flange class 300 AB 390

[15.35]

390

[15.35]

420

[16.54]

420

[16.54]

460

[18.11]

460

[18.11]

1⁄2” ANSI flange class 600 AC 390

[15.35]

390

[15.35]

420

[16.54]

420

[16.54]

460

[18.11]

460

[18.11]

1⁄2” ANSI flange class 900 AD 390

[15.35]

390

[15.35]

420

[16.54]

420

[16.54]

460

[18.11]

460

[18.11]

1⁄2” ANSI flange class 1500 BV 390

[15.35]

390

[15.35]

420

[16.54]

420

[16.54]

460

[18.11]

1⁄2” ANSI flange class 2500 BE 390

[15.35]

390

[15.35]

420

[16.54]

420

[16.54]

3⁄4” ANSI flange class 150 BA 390

[15.35]

390

[15.35]

420

[16.54]

420

[16.54]

460

[18.11]

460

[18.11]

3⁄4” ANSI flange class 300 BB 390

[15.35]

390

[15.35]

420

[16.54]

420

[16.54]

460

[18.11]

460

[18.11]

3⁄4” ANSI flange class 600 BC 390

[15.35]

390

[15.35]

420

[16.54]

420

[16.54]

460

[18.11]

460

[18.11]

3⁄4” ANSI flange class 900 BD 390

[15.35]

390

[15.35]

420

[16.54]

420

[16.54]

460

[18.11]

460

[18.11]

3⁄4” ANSI flange class 1500 AI 390

[15.35]

390

[15.35]

420

[16.54]

420

[16.54]

1” ANSI flange class 150 AE 390

[15.35]

390

[15.35]

420

[16.54]

420

[16.54]

460

[18.11]

460

[18.11]

625

[24.61]

1” ANSI flange class 300 AF 390

[15.35]

390

[15.35]

420

[16.54]

420

[16.54]

460

[18.11]

460

[18.11]

625

[24.61]

1” ANSI flange class 600 AG 390

[15.35]

390

[15.35]

420

[16.54]

420

[16.54]

460

[18.11]

460

[18.11]

625

[24.61]

1” ANSI flange class 900 AH 390

[15.35]

390

[15.35]

460

[18.11]

460

[18.11]

625

[24.61]

1” ANSI flange class 1500 AQ 390

[15.35]

390

[15.35]

460

[18.11]

1” ANSI flange class 2500 BN 390

[15.35]

390

[15.35]

11⁄2” ANSI flange class 150 AJ 460

[18.11]

460

[18.11]

625

[24.61]

11⁄2” ANSI flange class 300 AK 460

[18.11]

460

[18.11]

625

[24.61]

11⁄2” ANSI flange class 600 AL 460

[18.11]

460

[18.11]

625

[24.61]

11⁄2” ANSI flange class 900 AM 460

[18.11]

460

[18.11]

625

[24.61]

11⁄2” ANSI flange class 1500 BI 460

[18.11]

SLIP ON, PROCESS CONNECTION DIM. + FACING ACC. ANSI B16.5

INSTALLATION LENGTH IN MM [INCH]

Page 13 of 15

24

CLASSIC Series | TRICOR Coriolis Mass Flow Meters TRICOR Coriolis Mass Flow Meters | CLASSIC Series

25 21)Connections without installation length are not possible or need manufacturer release. Please contact the manufacturer.

Process connection21) Code TCM

0325

TCM

0650

TCM

1550

TCM

3100

TCM

5500

TCM

7900

TCM

028K

TCM

065K

TCM

230K

DN 40, EN flange PN 40 DE 460

[18.11]

460

[18.11]

625

[24.61]

DN 40, EN flange PN 63 EK 460

[18.11]

460

[18.11]

625

[24.61]

DN 40, EN flange PN 100 DF 460

[18.11]

460

[18.11]

625

[24.61]

DN 40, EN flange PN 160 EL 460

[18.11]

DN 40, EN flange PN 250 EM 460

[18.11]

DN 40, EN flange PN 400 EN 460

[18.11]

DN 50, EN flange PN 16 EO 625

[24.61]

830

[32.68]

DN 50, EN flange PN 40 DG 625

[24.61]

830

[32.68]

DN 50, EN flange PN 63 EP 625

[24.61]

830

[32.68]

DN 50, EN flange PN 100 DH 625

[24.61]

830

[32.68]

DN 65, EN flange PN 16 EQ 830

[32.68]

DN 65, EN flange PN 40 DQ 830

[32.68]

DN 65, EN flange PN 63 ER 830

[32.68]

DN 65, EN flange PN 100 ES 830

[32.68]

DN 80, EN flange PN 16 ET 830

[32.68]

915

[36.02]

DN 80, EN flange PN 40 DJ 830

[32.68]

915

[36.02]

DN 80, EN flange PN 63 EU 830

[32.68]

915

[36.02]

DN 80, EN flange PN 100 DK 830

[32.68]

915

[36.02]

DN 100, EN flange PN 16 EV 830

[32.68]

915

[36.02]

DN 100, EN flange PN 40 DL 830

[32.68]

915

[36.02]

DN 100, EN flange PN 63 EW 830

[32.68]

915

[36.02]

DN 100, EN flange PN 100 DM 830

[32.68]

915

[36.02]

SLIP ON, PROCESS CONNECTION DIM. + FACING ACC. EN 1092-1 FORM B

INSTALLATION LENGTH IN MM [INCH]

Process connection20) Code TCM

0325

TCM

0650

TCM

1550

TCM

3100

TCM

5500

TCM

7900

TCM

028K

TCM

065K

TCM

230K

DN 10, EN flange PN 40 DS 390

[15.35]

390

[15.35]

420

[16.54]

420

[16.54]

DN 10, EN flange PN 63 DZ 390

[15.35]

390

[15.35]

420

[16.54]

420

[16.54]

DN 10, EN flange PN 100 EA 390

[15.35]

390

[15.35]

420

[16.54]

420

[16.54]

DN 10, EN flange PN 160 EB 390

[15.35]

390

[15.35]

420

[16.54]

420

[16.54]

DN 10, EN flange PN 250 EC 390

[15.35]

390

[15.35]

420

[16.54]

420

[16.54]

DN 10, EN flange PN 400 ED 390

[15.35]

390

[15.35]

420

[16.54]

420

[16.54]

DN 15, EN flange PN 40 DA 390

[15.35]

390

[15.35]

420

[16.54]

420

[16.54]

460

[18.11]

460

[18.11]

DN 15, EN flange PN 63 EF 390

[15.35]

390

[15.35]

420

[16.54]

420

[16.54]

460

[18.11]

460

[18.11]

DN 15, EN flange PN 100 DB 390

[15.35]

390

[15.35]

420

[16.54]

420

[16.54]

460

[18.11]

460

[18.11]

DN 15, EN flange PN 160 EG 390

[15.35]

390

[15.35]

420

[16.54]

420

[16.54]

460

[18.11]

DN 15, EN flange PN 250 EH 390

[15.35]

390

[15.35]

420

[16.54]

420

[16.54]

460

[18.11]

DN 15, EN flange PN 400 EI 390

[15.35]

390

[15.35]

420

[16.54]

420

[16.54]

460

[18.11]

DN 20, EN flange PN 40 DT 460

[18.11]

460

[18.11]

DN 25, EN flange PN 40 DC 390

[15.35]

390

[15.35]

420

[16.54]

420

[16.54]

460

[18.11]

460

[18.11]

625

[24.61]

DN 25, EN flange PN 63 EJ 390

[15.35]

390

[15.35]

420

[16.54]

420

[16.54]

460

[18.11]

460

[18.11]

625

[24.61]

DN 25, EN flange PN 100 DD 390

[15.35]

390

[15.35]

420

[16.54]

420

[16.54]

460

[18.11]

460

[18.11]

625

[24.61]

DN 25, EN flange PN 160 DW 390

[15.35]

390

[15.35]

420

[16.54]

420

[16.54]

460

[18.11]

DN 25, EN flange PN 160

Mat.: 2.4602 DW 625

[24.61]

DN 25, EN flange PN 250 DP 390

[15.35]

390

[15.35]

420

[16.54]

420

[16.54]

460

[18.11]

DN 25, EN flange PN 400 DV 390

[15.35]

390

[15.35]

460

[18.11]

DN 32, EN flange PN 40 DR 460

[18.11]

460

[18.11]

625

[24.61]

SLIP ON, PROCESS CONNECTION DIM. + FACING ACC. EN 1092-1 FORM B

INSTALLATION LENGTH IN MM [INCH]

20) Connections without installation length are not possible or need manufacturer release. Please contact the manufacturer.

Page 14 of 15

26

CLASSIC Series | TRICOR Coriolis Mass Flow Meters TRICOR Coriolis Mass Flow Meters | CLASSIC Series

27 23)Connections without installation length are not possible or need manufacturer release. Please contact the manufacturer.

Process connection23) Code TCM

0325

TCM

0650

TCM

1550

TCM

3100

TCM

5500

TCM

7900

TCM

028K

TCM

065K

TCM

230K

1⁄4” NPT female thread FJ 110

[4.33]

110

[4.33]

140

[5.51]

140

[5.51]

3⁄4” NPT female thread FL 110

[4.33]

110

[4.33]

140

[5.51]

140

[5.51]

460

[18.11]

460

[18.11]

1⁄2” NPT female thread FK 110

[4.33]

110

[4.33]

140

[5.51]

140

[5.51]

460

[18.11]

460

[18.11]

2” NPT female thread FQ 880

[34.65]

1⁄4” G. female thread FB 110

[4.33]

110

[4.33]

140

[5.51]

140

[5.51]

3⁄8” G, female thread FR 110

[4.33]

110

[4.33]

140

[5.51]

140

[5.51]

3⁄4” G, female thread FC 110

[4.33]

110

[4.33]

140

[5.51]

140

[5.51]

460

[18.11]

460

[18.11]

1⁄2” G, female thread FA 110

[4.33]

110

[4.33]

140

[5.51]

140

[5.51]

460

[18.11]

460

[18.11]

FEMALE THREAD

INSTALLATION LENGTH IN MM [INCH]

Process connection22) Code TCM

0325

TCM

0650

TCM

1550

TCM

3100

TCM

5500

TCM

7900

TCM

028K

TCM

065K

TCM

230K

DN125, EN flange PN 16 EX 915

[36.02]

DN125, EN flange PN 40 DN 915

[36.02]

DN125, EN flange PN 63 EY 915

[36.02]

DN125, EN flange PN 100 DO 915

[36.02]

DN150, EN flange PN 16 DI 915

[36.02]

DN150, EN flange PN 40 DX 915

[36.02]

SLIP ON, PROCESS CONNECTION DIM. + FACING ACC. EN 1092-1 FORM B

INSTALLATION LENGTH IN MM [INCH]

Process connection22) Code TCM

0325

TCM

0650

TCM

1550

TCM

3100

TCM

5500

TCM

7900

TCM

028K

TCM

065K

TCM

230K

DN 32, PN40 DIN 2635 –

1.4404 [AISI 316L] Type C Face VO 460

[18.11]

460

[18.11]

625

[24.61]

DN 32, PN64 DIN 2636 –

1.4404 [AISI 316L] Type E Face VP 460

[18.11]

460

[18.11]

625

[24.61]

DN 32, PN100 DIN 2637 –

1.4404 [AISI 316L] Type E Face VQ 460

[18.11]

460

[18.11]

625

[24.61]

EN FLANGE WELD NECK

INSTALLATION LENGTH IN MM [INCH]

Process connection22) Code TCM

0325

TCM

0650

TCM

1550

TCM

3100

TCM

5500

TCM

7900

TCM

028K

TCM

065K

TCM

230K

1⁄2” Triclamp TA 220

[8.66]

220

[8.66]

250

[9.84]

250

[9.84]

DN 25 Triclamp

PN 16 DIN 32676 TL 210

[8.27]

210

[8.27]

240

[9.45]

240

[9.45]

460

[18.11]

460

[18.11]

625

[24.61]

TRICLAMP

INSTALLATION LENGTH IN MM [INCH]

22) Connections without installation length are not possible or need manufacturer release. Please contact the manufacturer.

Page 15 of 15

www.tricorflow.com

Contact

N & S AMERICA

AW-Lake Company

2440 W. Corporate Preserve Dr. #600

Oak Creek WI 53154 | USA

+1 414 574 4300

CHINA

KEM flow technology (Beijing) Co., Ltd.

Rm. 906, Block C, Ruipu Office Bldg, No. 15

HongJunYingNan Road

Chaoyang District, Beijing 100012 | China

+86 10 84929567

REST OF WORLD

KEM Küppers Elektromechanik GmbH

Liebigstraße 5

85757 Karlsfeld | Germany

+49 8131 59391-100

ASIEA/PACIFIC, MIDDLE EAST

KEM Instruments SEA Pte. Ltd.

UEN: 201717792Z

1003 Bukit Merah Central #06-32

Singapur 159836

+65 6274 1130

Original KEM/AWL Dokument: TCM_E68_CLASSIC_D_EN_180720_E002 I Copyright KEM/AWL, Subject to change without notice