Page 1 of 15
CLASSIC Series | TRICOR Coriolis Mass Flow Meters
www.tricorflow.com
The TCM CLASSIC product line meets general industrial requirements out of the box.
• TCE 8000 transmitters with an easy-to-use interface
• Economically-priced, non-calibrated but with excellent repeatability
• Optional custom-calibrated meters with high performance specifications
TECHNICAL DATASHEET
Page 2 of 15
2
CLASSIC Series | TRICOR Coriolis Mass Flow Meters TRICOR Coriolis Mass Flow Meters | CLASSIC Series
3
Description, Principle of operation ............................................... 02
Product Overview ........................................................................... 03
TCM Sensor – Technical Data for Liquids ...................................... 04
Accuracy for Liquids ...................................................................... 05
TCM Sensor – Technical Data for Gases......................................... 06
Accuracy for Gases ........................................................................ 07
TCE 8000/8100 Transmitter – Technical Data ................................ 08
TCE 6000 Transmitter – Technical Data ......................................... 09
TRD 8001 Remote Display - Technical Data .................................. 09
Dimensional Drawings................................................................... 10
Ordering Code TCM Meter (TRICOR CLASSIC Series) ..................... 17
Ordering Code TCE Transmitter (Series 8XXX) ............................... 07
Process Connections...................................................................... 19
TRICOR Connection Cable (TCC) for Panel-Mounted Housing ....... 25
Additional Accessories................................................................... 25
Contact ..........................................................................................26
CONTENT
Our passion is
your Process
Page 3 of 15
4
CLASSIC Series | TRICOR Coriolis Mass Flow Meters TRICOR Coriolis Mass Flow Meters | CLASSIC Series
5
PRODUCT OVERVIEW
Compact version
Exd housing: Wall mounted (remote version)
Housing: Panel mounted
(remote version) Version with TCE 6000 (including options)
DESCRIPTION
The TRICOR Coriolis Mass Flow Meters from TASI Flow are absolutely reliable and robust sensors in a variety of processes, performing
multiple measurements simultaneously with customizable process parameters and multiple communication languages. The TRICOR pro- duction team mechanically balances every meter, assuring the dual tubes are dynamically aligned and in perfect balance before flow be- gins. The unique design and cutting edge manufacturing procedures ensure a meter with the highest resistance to external influences.
FEATURES
• All-in-one instrument: direct measurement of mass flow,
density and temperature, calculated measurement of
volumetric flow
• No moving parts: low maintenance, no need for
recalibration
• Easy to install: no straight run of pipe required and multiple
mounting options available
• Mechanically balanced tubes and superior mechanical
design for best-in-class density measurement
• Exceptional mechanical design resists external interference
• API gravity reading in software
• Exceptional ease of use and fast setup time: we will pre- program your process parameters
• Frequency output up to 10,000 Hz resolution
• Superior meter calibration: DAkkS-Accreditation as per
DIN EN ISO/IEC 17025:2005
• Easily accessible, integrated meter diagnostics to verify
meter health & performance
• Hazardous area certifications:
ATEX, IECEx, cCSAus, EAC (TR-CU)
• Customized process connections available
ADDITIONAL OPTIONS
• Net Oil software
• High pressure designs available up to 345 bar [5,000 psi]
• Special calibrations for an oil viscosity up to 100 mm2
/s
• Integrated pressure compensation
• Customizable installation length
• Extended warranty
Coriolis Mass Flow Meters (TCM) operate with two parallel tubes with
coils that cause them to oscillate at their resonance frequency. Should
a measurement flow enter the measuring tube, Coriolis forces are
the result. Coriolis forces appear in oscillating systems when a mass
moves towards or away from a rotational axis. These forces act on the
inlet and outlet side in the opposite direction and minimally deform
the measuring tubes. The deflection of the measurement tubes is
captured by sensors on the inflow and outflow side. These two sensors
measure a phase shift that is proportional to the mass flow. The reso- nance frequency of the tubes varies depending on the density of the
medium to be measured. This effect is used to measure the density of
the medium. Since the elastic properties of the flow tubes depend on
the temperature, a temperature measurement is carried out for com- pensation. The primary characteristics such as mass flow rate, density
and temperature are measured with a single flow meter. The volume
flow can be determined based on the mass flow rate and density.
PRINCIPLE OF OPERATION
∆ T
phase shift = mass flow
t
Page 4 of 15
6
CLASSIC Series | TRICOR Coriolis Mass Flow Meters TRICOR Coriolis Mass Flow Meters | CLASSIC Series
7
TCM
0325
TCM
0650
TCM
1550
TCM
3100
TCM
5500
TCM
7900
TCM
028K
TCM
065K
TCM
230K
Max. Flow Rate (kg/h) 325 650 1,550 3,100 5,500 7,900 28,000 65,000 230,000
Max. Flow Rate (lb/min) 12 24 57 114 202 290 1,029 2,388 8,450
Basic Accuracy (Mass Flow) ±0.3 % of flow rate (option: 0.1 % of flow rate)
Basic Accuracy (Volume Flow) ±0.4 % of flow rate (option: 0.15 % of flow rate)
Repeatability ±0.05 % of flow rate
Zero Stability ±0.01 % of full scale
Density Range up to 2,500 kg/m3 [2.5 g/cm3
] (higher ranges on request)
Density Accuracy ±5.0 kg/m3 [±0.005 g/cm3
] (option: ±1.0 kg/m3 [±0.001 g/cm3
])
Density Repeatability ±0.5 kg/m3
[±0.0005 g/cm3
]
Process Temperature Range ±1 °C ±0.5 % of reading [±1.8 °F ±0.5 % of reading]
Temperature Repeatability ±0.2 °C [±0.36 °F]
Process and Ambient
Process Connections female thread 1/2“
adaptors for flanges, dairy and tri-clamp
flanges EN1092, ANSI B16.5, DIN2512,
threaded tri-clamp
Max. Pressure Standard 200 bar [2,900 psi]
option: 345 bar [5,000 psi] (not forASME) 100 bar [1,450 psi]
Pressure Drop at max. Flow for detail information please contact us
Process Temperature (non Ex) -40 °C ... +100 °C [-40 °F ... +212 °F] (standard)
-40 °C ... +150 °C [-40 °F ... +302 °F] (option)
-60 °C ... +200 °C [-76 °F ... +392 °F] (option)
Process Temperature (Ex) meter mount -40 °C ... +70 °C [-40 °F ... +158 °F] (T4) n/a
remote version -40 °C ... +70 °C [-40 °F ... +158 °F] (T4)
-40 °C ... +135 °C [-40 °F ... +275 °F] (T3)
-60 °C ... +200 °C [-76 °F ... +392 °F] (T2)
Ambient Temperature -40 °C ... +70 °C [-40 °F ... +158 °F]
Storage Temperature -40 °C ... +100 °C [-40 °F ... +212 °F]
Electr. Connections Remote screw type terminals
Electr. Connections Meter Mount none (internally connected to the electronics)
Ingress Protection IP65 (IP66/IP67 on request)
General
Tube Arrangement 2
seriell
2
parallel
2
seriell
2
parallel
2
parallel
2
parallel
2
parallel
2
parallel
2
parallel
Tube Inner Diameter 4 mm 4 mm 8 mm 8 mm 7 mm 9 mm 16 mm 28 mm 43 mm
Tube Material 1.4404 [AISI 316L]
Housing Material 1.4404 [AISI 316L]
Dimensions see dimensional drawings (page 10 - 11)
TCM SENSOR – TECHNICAL DATA FOR LIQUIDS
Calibration for Liquids and Gases: The TRICOR flowmeters are always factory calibrated with water.
Calibration Conditions: Water: 20 °C ... 25 °C [68 °F ... 77 °F], ambient temperature: 20 °C ... 25 °C [68 °F ... 77 °F].
All specifications are based on above mentioned calibration reference conditions, a flow calibration protocol is attached to each instrument.
Stated accuracy combines the effects of repeatability, linearity and hysteresis.
Typical flow dynamics based on max. flow rate is 100:1.
ACCURACY FOR LIQUIDS
Example for a standard TCM 0325
(Single-Point Calibration, Basic Accuracy: ±0.3 %)
325 kg/h * Zero Point (0.01 %) = 0.0325 kg/h
[12 lb/min * 0.01 % = 0.0012 lb/min]
325 kg/h * Basic Accuracy (0.3 %) = 0.975 kg/h
[12 lb/min * 0.3 % = 0.036 lb/min]
Result:
(0.0325 / 0.975) * 100 = 3.33 % (10.8 kg/h)
[(0.0012 / 0.036) * 100 = 3.33 % (0.4 lb/min)]
All Flow Rates ≥ 3.33 % or 10.8 kg/h (0.4 lb/min):
Measured Error = Basic Accuracy
All Flow Rates < 3.33 % or 10.8 kg/h (0.4 lb/min):
Measured Error = (Zero Point / Measured Value) * 100
Flow Rate of Full Scale Accuracy
± Basic Accuracy
±
Zero Point
Measured Value * 100
≥
Zero Point
Basic Accuracy * 100
< Zero Point
Basic Accuracy * 100
Standard
(Single-Point Calibration, Basic Accuracy: ±0.3 %)
Custom
(Five-Point-Calibration, Basic Accuracy: ±0.1 %)
Example for a custom TCM 0325
(Five-Point Calibration, Basic Accuracy: ±0.1 %)
325 kg/h * ZeroPoint (0.01 %) = 0.0325 kg/h
[12 lb/min * 0.01 % = 0.0012 lb/min]
325 kg/h * Basic Accuracy (0.1 %) = 0.325 kg/h
[12 lb/min * 0.1 % = 0.012 lb/min]
Result:
(0.0325 / 0.325) * 100 = 10 % (32.5 kg/h)
[(0.0012 / 0.012) * 100 = 10 % (1.2 lb/min)]
All flow rates ≥ 10 % or 32.5 kg/h (1.2 lb/min):
Measured error = Basic Accuracy
All flow rates < 10 % or 32.5 kg/h (1.2 lb/min):
Measured error = (Zero Point / Measured Value) * 100
Page 5 of 15
8
CLASSIC Series | TRICOR Coriolis Mass Flow Meters TRICOR Coriolis Mass Flow Meters | CLASSIC Series
9
TCM SENSOR – TECHNICAL DATA FOR GASES
TCM
0325
TCM
0650
TCM
1550
TCM
3100
TCM
5500
TCM
7900
TCM
028K
TCM
065K
TCM
230K
Nom. Flow Rate (kg/h)1) 3) 78 177 333 740 910 1,430 5,100 15,650 48,900
Nom. Flow Rate (lb/min)1) 3) 3 7 12 27 34 53 188 575 1,797
Nom. Flow Rate (Nm3
/h)1) 2) 109 247 464 1,031 1,268 1,993 7,109 21,813 68,157
Nom. Flow Rate (SCFM)1) 2) 64 146 273 607 747 1,173 4,184 12,838 40,115
Basic Accuracy ±1 % of flow rate (option: ±0.5 % of flow rate)
Repeatability ±0,25 % of flow rate
Zero Stability (kg/h) 0.0325 0.065 0.155 0.31 0.55 0.79 2.8 6.5 23
Zero Stability (lb/min) 0.0012 0.0024 0.0057 0.0114 0.020 0.029 0.103 0.239 0.845
Density Range see comment3)
Density Accuracy ±5.0 kg/m3
[±0.005 g/cm3
] (option: ±1.0 kg/m3
[±0.001 g/cm3
]
Density Repeatability ±0.5 kg/m3
[±0.0005 g/cm3
]
Process Temperature Range ±1 °C ±0.5 % of reading [±1.8 °F ±0.5 % of reading]
Temperature Repeatability ±0.2 °C [±0.36 °F]
Prozess-/Umgebungsbedingungen
Process Connections female thread 1/2“
adaptors for flanges, dairy and tri-clamp
flanges EN1092, ANSI B16.5, DIN2512,
threaded tri-clamp
Max. Pressure Standard 200 bar [2,900 psi]
option: 345 bar [5,000 psi] (ot for ASME) 100 bar [1,450 psi]
Pressure Drop at max. Flow for detail information please contact us
Process Temperature (non Ex) -40 °C ... +100 °C [-40 °F ... +212 °F] (standard)
-40 °C ... +150 °C [-40 °F ... +302 °F] (option)
-60 °C ... +200 °C [-76 °F ... +392 °F] (option)
Process Temperature (Ex) meter mount -40 °C ... +70 °C [-40 °F ... +158° F] (T4) n/a
remote version -40 °C ... +70 °C [-40 °F ... +158 °F] (T4)
-40 °C ... +135 °C [-40 °F ... +275 °F] (T3)
-60 °C ... +200 °C [-76 °F ... +392 °F] (T2)
Ambient Temperature -40 °C ... +70 °C [-40 °F ... +158 °F]
Storage Temperature -40 °C ... +100 °C [-40 °F ... +212 °F]
Electr. Connections Remote screw type terminals
Electr. Connections Meter Mount none (internally connected to the electronics)
Ingress Protection IP65 (IP66/IP67 on request)
General
Tube Arrangement 2
serial
2
parallel
2
serial
2
parallel
2
parallel
2
parallel
2
parallel
2
parallel
2
parallel
Tube Inner Diameter 4 mm 4 mm 8 mm 8 mm 7 mm 9 mm 16 mm 28 mm 43 mm
Tube Material 1.4404 [AISI 316L]
Housing Material 1.4404 [AISI 316L]
Dimensions see dimensional drawings (page 10 - 11)
Max. allowed flow velocity (Ma 0.5).
For gas applications, flow rate and pressure drop for individual sensor sizes are dependent on operating temperature, pressure and fluid composition.
Therefore, when selecting a sensor for any particular gas application, please use the the TSP (TRICOR Sizing Program) or contact us.
1) Nominal flow rates that produce approximately 3 bar [43 psi] pressure drop for natural gas at 50 bar [725 psi] operational pressure. 2) Normal reference conditions (Nm3
/h) are 1,013 bar und 0 °C. Standard (SCFM) reference conditions are 14.7 psi und 60 °F. 3) Flow rate and density range depend on the gas density and the pressure range.
ACCURACY FOR GASES
4) For Ex1, Ex3, EAC (TR-CU) the electronic is only available in aluminum housing. 5) Only with remote electronics.
EX CERTIFICATIONS
ATEX (Ex) Zone 1: Group IIC or IIB, T2...T4
ATEX (Exn) Zone 2: II 3G Ex nA IIC T2...T4 Gc
IECEx (Ex) Zone 1: Group IIC or IIB, T2...T4
cCSAus (Ex1)4) Class 1, Division 1: Group A, B, C, D or C, D, T2...T4
ATEX + IECEx + cCSAus triple
approval (Ex3)4) 5)
Zone 1: Group IIC or IIB, T2...T4 and
Class 1, Division 1: Group A, B, C, D or C, D, T2...T4
EAC (TR-CU)4) Group IIC or IIB, T2 ... T4
Flow Rate of Full Scale Accuracy
± Basic Accuracy
±
Zero Point
Measured Value * 100
≥
Zero Point
Basic Accuracy * 100
< Zero Point
Basic Accuracy * 100
Standard
(Single-Point Calibration, Basic Accuracy: ±1 %)
Custom
(Five-Point-Calibration, Basic Accuracy: ±0.5 %)
Example for a standard TCM 0325
(Single-Point Calibration, Basic Accuracy: ±1 %)
325 kg/h * Zero Point (0.01 %) = 0.0325 kg/h
[12 lb/min * 0.01 % = 0.0012 lb/min]
325 kg/h * Basic Accuracy (1 %) = 3.25 kg/h
[12 lb/min * 1 % = 0.12 lb/min]
Result:
(0.0325 / 3.25) * 100 = 1 % (3.25 kg/h)
[(0.0012 / 0.12) * 100 = 1 % (0.12 lb/min)]
All Flow Rates ≥ 1 % or 3.25 kg/h (0.12 lb/min):
Measured Error = Basic Accuracy
All Flow Rates < 1 % or 3.25 kg/h (0.12 lb/min):
Measured Error = (Zero Point / Measured Value) * 100
Example for a custom TCM 0325
(Five-Point Calibration, Basic Accuracy: ±0.5 %)
325 kg/h * ZeroPoint (0.01 %)= 0.0325 kg/h
[12 lb/min * 0.01 % = 0.0012 lb/min]
325 kg/h * Basic Accuracy (0.5 %) = 1.625 kg/h
[12 lb/min * 0.5 % = 0.06 lb/min]
Result:
(0.0325 / 1.625) * 100 = 2 % (6.5 kg/h)
[(0.0012 / 0.06) * 100 = 2% (0.24 lb/min)]
All flow rates ≥ 2 % or 6.5 kg/h (0.24 lb/min):
Measured error = Basic Accuracy
All flow rates < 2 % or 6.5 kg/h (0.24 lb/min):
Measured error = (Zero Point / Measured Value) * 100
Page 6 of 15
10
CLASSIC Series | TRICOR Coriolis Mass Flow Meters TRICOR Coriolis Mass Flow Meters | CLASSIC Series
11
TCE 8000/8100 TRANSMITTER – TECHNICAL DATA
General
Display back-lit LCD screen, 132 x 32 dot
Supply Voltage 24 V DC, ±20 % or 90 ... 264 V (version dependent)
Programming via front keyboard or Windows-based TRICOR configurator program (Modbus)
Interface RS485 (Modbus-RTU), option HART®, Foundation Fieldbus® , other options on request
EMV according to EN 61000-6-4 and 61000-6-2
Power Consumption max. 6 W
ExD Housing: Wall-mounted
Dimensions see dimensional drawing (page 12 - 13)
Electrical Connections cage clamp terminals
Cable Glands for 7-13 mm cables
Housing Material aluminum diecast (option: 1.4404 [AISI 316L])
Protection Class IP65 (IP66/IP67 on request)
Weight with aluminum diecast housing: 3.8 kg [8.3 lb] with 3 m cable
with 1.4404 [AISI 316L] housing: 6.15 kg [13.56 lb]
Temperature ambient: -40 °C ... +70 °C [-40 °F ... +158 °F]
storage and transport: -40 °C ... +80 °C [-40 °F ... +176 °F]
Housing: Panel-mounted (only TCE 8000)
Dimensions see dimensional drawing (page 15)
Electrical Connections cage clamp terminals
Housing Material Noryl
Protection Class front: IP50, rear: IP30
Weight 0.4 kg [0.88 lb]
Temperature ambient: ±0 °C ... +60 °C [32 °F ... +140 °F]
storage and transport: -20 °C ... +70 °C [-4 °F ... +158 °F]
Analog Output
Current Outputs (2x) 4 ... 20 mA passive, two-wire, isolated
Resolution 14 bit
Linearity ±0.05 % of full scale
Temperature Drift 0.05 % per 10 K
Load < 620 Ω (at 24 V supply)
Output Value programmable: flow, total, density, temperature
Pulse Output
Frequency Range 0.5 - 10,000 Hz (in TOTAL mode: 0 - 100 Hz)
Output Signal active push pull output for flow rate
Status In- and Output
Status Output push pull programmable
(in FREQUENCY mode: 0.5 - 10,000 Hz)
Control Input programmable
Analog Input (option)
Input Type 4 ... 20 mA active for two-wire passive pressure sensor
Resolution 12 bit
Linearity ±0.05 % of full scale
Temperature Drift 0.05 % per 10 K
Supply Voltage > 20 V (at 20 mA sensor current)
General
Supply Voltage 24 V DC, ±20 %
Programming via TRD 8001 or via interface
Interface RS485, USB (option)
EMC according to EN 61000-6-4 and EN 61000-6-2
Power Consumption max. 4 W
Dimensions see dimensional drawing (page 15)
Electrical Connections connectors M12
Housing Material aluminum diecast
Temperature ambient: : -40 °C ... +70 °C [-40 °F ... +158 °F]
storage and transport: -40 °C ... +80 °C [-40 °F ... +176 °F]
Protection Class IP65
Analog Output
Current Output 4 ... 20 mA active
Resolution 14 bit
Linearity ±0.05 %
Temperature Drift 0.05 % per 10 K
Load < 800 Ω
Output Value programmable: flow, total, density, temperature
Pulse Output
Frequency Range 0.5 - 10,000 Hz (for ESTA (OPTV receiver) 0.5 - 5,000 Hz)
Output Signal active push pull output for flow rate, optional: insulated optical frequency output
Status In- and Output
Status Output push pull programmable (option)
(in TOTAL mode: 0.5 - 100 Hz)
Control Input programmable (standard: 1 input/option: 2 inputs)
option: insulated optical control input
TCE 6000 TRANSMITTER – TECHNICAL DATA
Display back-lit LCD screen, 132 x 32 dot
Supply Voltage via interface
Programming via front keyboard
Interface to TCE RS485
EMC according to EN 61000-6-4 and 61000-6-2
Dimensions see dimensional drawing (page 16)
Electrical Connections connectors M12
Housing Material ABS-FR (plastic, flame retardant)
Protection Class IP64
Weight 0.4 kg [0.88 lb]
Temperature operation: ±0 °C ... +60 °C [32 °F ... +140 °F]
storage and transport: -20 °C ... +80 °C [- 4°F ... +176 °F]
Wall Mount hidden screws
TRD 8001 REMOTE DISPLAY – TECHNICAL DATA
Note: For parameterization of the flow meter, the interface may be used.
Prerequisite: Parameter setting is not allowed during active ESTA operation.
Page 7 of 15
12
CLASSIC Series | TRICOR Coriolis Mass Flow Meters TRICOR Coriolis Mass Flow Meters | CLASSIC Series
13
TCM 0325 TO TCM 0650
L
Y
H
22mm
0.87in G E
60mm
2.36in
70mm
2.76in
D
A
Dokumentennr Dokumentname Datum Name
JJ/MM.NNXX TCM 325_3100 Datenblatt Allgemein-DE Mittwoch, 10. August 2016
09:56:13 griebel
Sensor Type A D E G6) H L7) Y
TCM 0325 214 mm
[8.43 in] M6 10 15 mm
[0.59 in] G 1⁄2“ 182 mm
[7.17 in]
110 mm
[4.33 in]
216 mm
[8.50 in]
TCM 0650 214 mm
[8.43 in] M6 10 15 mm
[0.59 in] G 1⁄2“ 182 mm
[7.17 in]
110 mm
[4.33 in]
216 mm
[8.50 in]
6) Other connections on request. 7) Further lengths on request.
TCM 1550 TO TCM 3100
L
Y
H
A 59mm
2.32in
22mm
0.87in G E D
70mm
2.76in
Dokumentennr Dokumentname Datum Name
16/08.0011 TCM 1550_3100 compact DE Mittwoch, 10. August 2016
10:06:24 griebel
Sensor Type A D E G6) H L7) Y
TCM 1550 350 mm
[13.78 in] M6 10 18 mm
[0.71 in] G 1⁄2“ 280 mm
[11.02 in]
140 mm
[5.51 in]
384 mm
[15.12 in]
TCM 3100 350 mm
[13.78 in] M6 10 18 mm
[0.71 in] G 1⁄2“ 280 mm
[11.02 in]
140 mm
[5.51 in]
384 mm
[15.12 in]
874mm
34.4in
974mm
38.37in
704mm
27.73in
32mm
1.26in
891mm
35.07in
230mm
9.06in
TCM 230K
TCM 5500 TO TCM 065K
Sensor Type B C H L8) I.D. Connection
TCM 5500, 7900 61 mm
[2.40 in]
204 mm
[8.03 in]
260 mm
[10.24 in]
460 mm
[18.11 in]
Ø 13 mm
[Ø 0.51 in] on request
TCM 028K 80 mm
[3.15 in]
253 mm
[9.96 in]
315 mm
[12.40 in]
625 mm
[24.61 in]
Ø 23 mm
[Ø 0.91 in] on request
TCM 065K 151 mm
[5.94 in]
387 mm
[15.24 in]
480 mm
[18.90 in]
830 mm
[32.68 in]
Ø 40 mm
[Ø 1.57 in] on request
L
H
B
C
ID
Dokumentennr Dokumentname Datum Name
16/08.0005 TCM Datenblatt Allgemein-DE_EN Mittwoch, 10. August 2016
08:08:40 griebel
8) Further lengths on request..
Page 8 of 15
14
CLASSIC Series | TRICOR Coriolis Mass Flow Meters TRICOR Coriolis Mass Flow Meters | CLASSIC Series
15
WALL-MOUNT ELECTRONICS TCE 8000/8100
147mm
5.79in
110mm
4.33in 138mm
5.45in
10mm
0.39in
10,50mm
0.41in
203mm
7.99in
116mm
4.57in
118mm
4.65in
147mm
5.79in
110mm
4.33in
68mm
2.68in
203mm
7.99in
118mm
4.65in
166mm
6.52in
METER-MOUNT ELECTRONICS TCE 8000/8100 METER-MOUNT ELECTRONICS TCE 8000/8100 WITH BLIND COVER
147mm
5.79in
110mm
4.33in
68mm
2.68in
184mm
7.24in
166mm
6.52in
99mm
3.90in
Dokumentennr Dokumentname Datum Name
JJ/MM.NNXX TCE 80xx-24 BG-DE Donnerstag, 6. Oktober 2016
13:44:49 griebel
147mm
5.80in
110mm
4.32in
68mm
2.68in
234mm
9.19in
203mm
7.99in
118mm
4.65in
Dokumentennr Dokumentname Datum Name
JJ/MM.NNXX TCE 80xx-XXX BG - HT DE Donnerstag, 29. September
2016 14:50:08 griebel
METER-MOUNT ELECTRONICS TCE 8000/8100 HIGH TEMPERATURE
Page 9 of 15
16
CLASSIC Series | TRICOR Coriolis Mass Flow Meters TRICOR Coriolis Mass Flow Meters | CLASSIC Series
17
STANDARD CONNECTION HEAD (A)
88mm
3.45in
68mm
2.68in
57mm
2.23in
72mm
2.82in
115mm
4.52in
Dokumentennr Dokumentname Datum Name
JJ/MM.NNXX TCE JB ALU Mittwoch, 30. März 2016
09:25:15 griebel
101mm
3.96in
85mm
3.33in 105mm
4.14in
77mm
3.01in
63mm
2.48in
HIGH TEMPERATURE CONNECTION HEAD (H)
PANEL-MOUNTED HOUSING
96mm
3.78in
96mm
3.78in
83mm
3.27in
96mm
3.80in
8mm
0.31in
143mm
5.64in
46mm
1.81in
66mm
2.60in
100mm
3.94in
Dokumentennr Dokumentname Datum Name
TCE 60xx BG_DAT_DE Mittwoch, 2. Mai 2018 12:33:22 griebel
METER-MOUNT ELECTRONICS TCE 6000 (F)
Page 10 of 15
18
CLASSIC Series | TRICOR Coriolis Mass Flow Meters TRICOR Coriolis Mass Flow Meters | CLASSIC Series
19
REMOTE DISPLAY TRD 8001
120mm
4.72in
90mm
3.54in 48mm
1.89in
16mm
0.63in
Dokumentennr Dokumentname Datum Name
16/08.0014 TRD 8001 -DE Mittwoch, 10. August 2016
10:53:26 griebel
ORDERING CODE TCM METER (TRICOR CLASSIC SERIES)
9) For connections not indicated with installation length, please contact manufacturer. 10)For TCM compact version with Ex-protection temperature class T4 only.
11)Ex-protection only available in the option Exn. TCE 6000 electronic is not applicable for TCM 230K.
12)Other interfaces on request.
13)For Ex1, Ex3, EAC (TR-CU) the electronic is only available in aluminum housing.
14)Only with remote electronics.
TCM XXXX - XX - X X X X - X X X X - Ex - XX
Process Connections9)
see page 17 ff XX
Mechanical Options
Medium Temperature Range
-40 °C ... +100 °C [-40 °F ... +212 °F] S
-40 °C ... +150 °C [-40 °F ... +302 °F], Exmax: 135 °C [275 °F] H
-40 °C ... +70 °C [-40 °F ... +158 °F], Ex, compact E
-60 °C ... +200 °C [-76 °F ... +392 °F] T
Pressure Range
With rupture disc max. 4 bar [58 psi] G
Mechanical Design
Standard S
Face to Face Length
Standard (other length on request) S
Electronics Options
Electronics Type
Junction box, 1.4404 [316L] H Z Z S
Meter mount, die cast aluminum housing for 1⁄2” NPT cable glands10) C
Meter mount, die cast aluminum housing for M20x1.5 cable glands10) K
Meter mount, stainless steel housing for 1⁄2” NPT cable glands10) M
Meter mount, stainless steel housing for M20x1.5 cable glands10) O
Meter mount electronics TCE 600011) F
Interface12)
RS485 (Modbus RTU) S
RS485 (Modbus RTU) and HART® A
RS485 (Modbus RTU) + FF (not with Ex) B
FF (Foundation Fieldbus®
) D
RS485 (Modbus RTU) + USB (only TCE 6000) F
Not used Z
Supply Voltage
24 V DC D
90 ... 264 V AC M
Not used Z
Options
Pressure compensation, 4 ... 20 mA input A
8 pin I/O connector (TCE 6000 only) B
Optical I/O (TCE 6000 only) C
No option S
EX-Protection
ATEX + IECEx Zone1: Group IIC or IIB, T2...T4 Ex
ATEX Zone 2: II 3G Ex nA IIC, T2...T4 Gc Exn
cCSAus: Class 1, Division 1: Group A, B, C, D or C, D, T2...T413) Ex1
Ex3
EAC (TR-CU): Group IIC or IIB, T2 ... T413) ExR
Special Options
NOC (Net Oil Computer) 01
9) For connections not indicated with installation length, please contact manufacturer.
10) For TCM compact version with Ex-protection temperature class T4 only.
11) Ex-protection only available in the option Exn. TCE 6000 electronic is not applicable for TCM 230K.
12) Other interfaces on request.
13) For Ex1, Ex3, EAC (TR-CU) the electronic is only available in aluminum housing.
14) Only with remote electronics.
ATEX+IECEx: Zone 1: Group IIC or IIB, T2...T4 and
cCSAus: Class 1, Division 1: Group A, B, C, D or C, D, T2...T413) 14)
Page 11 of 15
20
CLASSIC Series | TRICOR Coriolis Mass Flow Meters TRICOR Coriolis Mass Flow Meters | CLASSIC Series
21
15)Only for TCE 80XX.
16)Other interfaces on request.
17)For Ex1, Ex3, EAC (TR-CU) the electronic is only available in aluminum housing.
ORDERING CODE TCE TRANSMITTER (SERIES 8XXX)
TCE 8 X X X - X - X X X X - XX - XX
Housing material: Aluminum 8 0
Housing material: stainless steel 1.4404 [AISI 316L] 8 1
Electronics for TCM 0325 to TCM 7900 0 1
Electronics for TCM 028K to TCM 065K 1 1
Electronics for TCM 230K 1 2
Housing
Wall mount (housing for 1⁄2” NPT cable glands) W
Wall mount (housing for M20x1.5 cable glands) I
Panel mount15) S
Panel mount, wide, for "Ex", "associated equipment"15) L
Options
Interface16)
RS485 (Modbus RTU) S
R485 (Modbus RTU) + HART® A
Supply Voltage
24 V DC + 90 ... 264 V AC (only housing S+L) B
24 V DC D
90 ... 264 V AC (only housing W, I) M
Electronic Options
Standard S
Pressure compensation, 4 ... 20 mA input A
Cable Length
3 Meters [≈ 10 ft.], Standard (high temperature) S (H)
6 Meters [≈ 20 ft.] (high temperature) B (I)
10 Meters [≈ 33 ft.] (high temperature) C (J)
15 Meters [≈ 49 ft.] (high temperature) D (O)
20 Meters [≈ 65 ft.] (high temperature) E (P)
F
D-SUB Connector, (housing L+S) seperate cable required N
Ex-Protection
ATEX + IECEx Zone1: Group IIC or IIB, T2...T4 Ex
ATEX Zone 2: II3G Ex nA IIC, T2...T4 Gc Exn
cCSAus: Class 1, Division 1: Group A, B, C, D or C, D, T2...T417) Ex1
Ex3
EAC (TR-CU): Group IIC or IIB, T2 ... T417) ExR
Special Options
NOC (Net Oil Computer) 01
15) Only for TCE 80XX.
16) Other interfaces on request.
17) For Ex1, Ex3, EAC (TR-CU) the electronic is only available in aluminum housing.
ATEX+IECEx, Zone 1: Group IIC or IIB, T2...T4 and
cCSAus: Class 1, Div. 1: Group A, B, C, D or C, D, T2...T417)
3 Meters [≈ 10 ft.], offshore cable
(halogen-free, flame propagation test: IEC 60332-1, combustion test: IEC 60754-2)
TCC X X - X X
Cable Connector TCE Connector TCM Devices
Standard cable SUB-D, 9-pin cable end sleeves (8-pol.) TCE 8**1-S- 0 2
TCE 8**1-L- Standard cable SUB-D, 9-pin/ cable end sleeves (8-pol.) TCE 8**1-S- 0 4
Din-Rail mounting TCE 8**1-L- High temperature cable SUB-D, 9-pin cable end sleeves (8-pol.) TCE 8**1-S- 0 9
TCE 8**1-L- High temperature cable SUB-D, 9-pin/ cable end sleeves (8-pol.) TCE 8**1-S- 1 0
Din-Rail mounting TCE 8**1-L- Length
3 meter (Standard) [≈ 10 ft.] 0 3
6 meter [≈ 20 ft.] 0 6
10 meter [≈ 33 ft.] 1 0
15 meter [≈ 49 ft.] 1 5
20 meter [≈ 66 ft.] 2 0
TRICOR CONNECTION CABLE (TCC) FOR PANEL-MOUNTED HOUSING
Cable Specifications/Connections
ADDITIONAL ACCESSORIES
Accessories for TCE 8* electronic Model Code
USB interface cable to RS485, 1.8 m (TRICOR configurator) CON.USB.RS-ISO
IP65 Protection for TCE-80**-L IPS 9-14
IP65 Protection for TCE-80**-S IPS 9-9
Adapter TCE-80**-S and TCE-80**-L for rail mounting HSA 96
Accessories for TCE 6000 electronic Model Code
Remote display for TCE 6000 TRD 8001
Connection cable TRD 8001 to TCE 6000, 2 m TRD-TCE-6-2
Connection cable TRD 8001 to TCE 6000, 5 m TRD-TCE-6-5
USB Cable, USB to mini USB M12, 2 m KAB-USB-TCE
RS485 to USB connector cable 3 m
for TCE 6000; versions FSDS;FFDB, FSDC
KAB-RS485-TCE-ISO
Pneumatic Power Gen. Plug M8, 3 pin, 2.5 m cable
for TCE 6000 Version FSDC; 7.5 W, 24 V DC
TCE 6000-FSDC-SET-PPG
Light pulse emitter and receiver, DIN-rail for TCE 6000 Version FSDC OPTV-02/XO
Fiber optic cable for TCE 6000 Version FSDC for FOP 50/60, 10 m (5.5 mm) LW-LA-10
Service and calibration Model Code
DAkkS-Calibration (ILAC) according to DIN EN ISO/IEC 17025:2005 DAkkS-Kalibrierung
Oxygen cleaning TCM Reinigung Sauerstoff TCM
Inspection certificate 3.1 according to DIN 50 049/EN 10204 3.WKZ-0100
TAG Plate 1.4404 [AISI 316L] TCM-Tag-Plate-1.4404
Page 12 of 15
22
CLASSIC Series | TRICOR Coriolis Mass Flow Meters TRICOR Coriolis Mass Flow Meters | CLASSIC Series
23 19)Connections without installation length are not possible or need manufacturer release. Please contact the manufacturer.
Process connection19) Code TCM
0325
TCM
0650
TCM
1550
TCM
3100
TCM
5500
TCM
7900
TCM
028K
TCM
065K
TCM
230K
2” ANSI flange class 150 AN 625
[24.61]
830
[32.68]
2” ANSI flange class 300 AO 625
[24.61]
830
[32.68]
2” ANSI flange class 600 AP 625
[24.61]
830
[32.68]
2” ANSI flange class 900 AR 625
[24.61]
830
[32.68]
2” ANSI flange class 1500 BU 830
[32.68]
21⁄2” ANSI flange class 150 BT 830
[32.68]
21⁄2” ANSI flange class 300 BY 830
[32.68]
21⁄2” ANSI flange class 600 BQ 830
[32.68]
21⁄2” ANSI flange class 900 BW 830
[32.68]
3” ANSI flange class 150 AS 625
[24.61]
830
[32.68]
915
[36.02]
3” ANSI flange class 300 AT 830
[32.68]
915
[36.02]
3” ANSI flange class 600 AU 830
[32.68]
915
[36.02]
3” ANSI flange class 900 AV 830
[32.68]
915
[36.02]
4” ANSI Flange class 150 AW 830
[32.68]
915
[36.02]
4” ANSI flange class 300 AX 830
[32.68]
915
[36.02]
4” ANSI flange class 600 AY 830
[32.68]
915
[36.02]
4” ANSI flange class 900 AZ 830
[32.68]
915
[36.02]
5” ANSI flange class 150 BF 915
[36.02]
5” ANSI flange class 300 BG 915
[36.02]
5” ANSI flange class 600 BH 915
[36.02]
5” ANSI flange class 900 BJ 915
[36.02]
6” ANSI flange class 150 BM 915
[36.02]
6” ANSI flange class 600 BX 915
[36.02]
SLIP ON, PROCESS CONNECTION DIM. + FACING ACC. ANSI B16.5
INSTALLATION LENGTH IN MM [INCH]
18) Connections without installation length are not possible or need manufacturer release. Please contact the manufacturer.
Process connection18) Code TCM
0325
TCM
0650
TCM
1550
TCM
3100
TCM
5500
TCM
7900
TCM
028K
TCM
065K
TCM
230K
1⁄2” ANSI flange class 150 AA 390
[15.35]
390
[15.35]
420
[16.54]
420
[16.54]
460
[18.11]
460
[18.11]
1⁄2” ANSI flange class 300 AB 390
[15.35]
390
[15.35]
420
[16.54]
420
[16.54]
460
[18.11]
460
[18.11]
1⁄2” ANSI flange class 600 AC 390
[15.35]
390
[15.35]
420
[16.54]
420
[16.54]
460
[18.11]
460
[18.11]
1⁄2” ANSI flange class 900 AD 390
[15.35]
390
[15.35]
420
[16.54]
420
[16.54]
460
[18.11]
460
[18.11]
1⁄2” ANSI flange class 1500 BV 390
[15.35]
390
[15.35]
420
[16.54]
420
[16.54]
460
[18.11]
1⁄2” ANSI flange class 2500 BE 390
[15.35]
390
[15.35]
420
[16.54]
420
[16.54]
3⁄4” ANSI flange class 150 BA 390
[15.35]
390
[15.35]
420
[16.54]
420
[16.54]
460
[18.11]
460
[18.11]
3⁄4” ANSI flange class 300 BB 390
[15.35]
390
[15.35]
420
[16.54]
420
[16.54]
460
[18.11]
460
[18.11]
3⁄4” ANSI flange class 600 BC 390
[15.35]
390
[15.35]
420
[16.54]
420
[16.54]
460
[18.11]
460
[18.11]
3⁄4” ANSI flange class 900 BD 390
[15.35]
390
[15.35]
420
[16.54]
420
[16.54]
460
[18.11]
460
[18.11]
3⁄4” ANSI flange class 1500 AI 390
[15.35]
390
[15.35]
420
[16.54]
420
[16.54]
1” ANSI flange class 150 AE 390
[15.35]
390
[15.35]
420
[16.54]
420
[16.54]
460
[18.11]
460
[18.11]
625
[24.61]
1” ANSI flange class 300 AF 390
[15.35]
390
[15.35]
420
[16.54]
420
[16.54]
460
[18.11]
460
[18.11]
625
[24.61]
1” ANSI flange class 600 AG 390
[15.35]
390
[15.35]
420
[16.54]
420
[16.54]
460
[18.11]
460
[18.11]
625
[24.61]
1” ANSI flange class 900 AH 390
[15.35]
390
[15.35]
460
[18.11]
460
[18.11]
625
[24.61]
1” ANSI flange class 1500 AQ 390
[15.35]
390
[15.35]
460
[18.11]
1” ANSI flange class 2500 BN 390
[15.35]
390
[15.35]
11⁄2” ANSI flange class 150 AJ 460
[18.11]
460
[18.11]
625
[24.61]
11⁄2” ANSI flange class 300 AK 460
[18.11]
460
[18.11]
625
[24.61]
11⁄2” ANSI flange class 600 AL 460
[18.11]
460
[18.11]
625
[24.61]
11⁄2” ANSI flange class 900 AM 460
[18.11]
460
[18.11]
625
[24.61]
11⁄2” ANSI flange class 1500 BI 460
[18.11]
SLIP ON, PROCESS CONNECTION DIM. + FACING ACC. ANSI B16.5
INSTALLATION LENGTH IN MM [INCH]
Page 13 of 15
24
CLASSIC Series | TRICOR Coriolis Mass Flow Meters TRICOR Coriolis Mass Flow Meters | CLASSIC Series
25 21)Connections without installation length are not possible or need manufacturer release. Please contact the manufacturer.
Process connection21) Code TCM
0325
TCM
0650
TCM
1550
TCM
3100
TCM
5500
TCM
7900
TCM
028K
TCM
065K
TCM
230K
DN 40, EN flange PN 40 DE 460
[18.11]
460
[18.11]
625
[24.61]
DN 40, EN flange PN 63 EK 460
[18.11]
460
[18.11]
625
[24.61]
DN 40, EN flange PN 100 DF 460
[18.11]
460
[18.11]
625
[24.61]
DN 40, EN flange PN 160 EL 460
[18.11]
DN 40, EN flange PN 250 EM 460
[18.11]
DN 40, EN flange PN 400 EN 460
[18.11]
DN 50, EN flange PN 16 EO 625
[24.61]
830
[32.68]
DN 50, EN flange PN 40 DG 625
[24.61]
830
[32.68]
DN 50, EN flange PN 63 EP 625
[24.61]
830
[32.68]
DN 50, EN flange PN 100 DH 625
[24.61]
830
[32.68]
DN 65, EN flange PN 16 EQ 830
[32.68]
DN 65, EN flange PN 40 DQ 830
[32.68]
DN 65, EN flange PN 63 ER 830
[32.68]
DN 65, EN flange PN 100 ES 830
[32.68]
DN 80, EN flange PN 16 ET 830
[32.68]
915
[36.02]
DN 80, EN flange PN 40 DJ 830
[32.68]
915
[36.02]
DN 80, EN flange PN 63 EU 830
[32.68]
915
[36.02]
DN 80, EN flange PN 100 DK 830
[32.68]
915
[36.02]
DN 100, EN flange PN 16 EV 830
[32.68]
915
[36.02]
DN 100, EN flange PN 40 DL 830
[32.68]
915
[36.02]
DN 100, EN flange PN 63 EW 830
[32.68]
915
[36.02]
DN 100, EN flange PN 100 DM 830
[32.68]
915
[36.02]
SLIP ON, PROCESS CONNECTION DIM. + FACING ACC. EN 1092-1 FORM B
INSTALLATION LENGTH IN MM [INCH]
Process connection20) Code TCM
0325
TCM
0650
TCM
1550
TCM
3100
TCM
5500
TCM
7900
TCM
028K
TCM
065K
TCM
230K
DN 10, EN flange PN 40 DS 390
[15.35]
390
[15.35]
420
[16.54]
420
[16.54]
DN 10, EN flange PN 63 DZ 390
[15.35]
390
[15.35]
420
[16.54]
420
[16.54]
DN 10, EN flange PN 100 EA 390
[15.35]
390
[15.35]
420
[16.54]
420
[16.54]
DN 10, EN flange PN 160 EB 390
[15.35]
390
[15.35]
420
[16.54]
420
[16.54]
DN 10, EN flange PN 250 EC 390
[15.35]
390
[15.35]
420
[16.54]
420
[16.54]
DN 10, EN flange PN 400 ED 390
[15.35]
390
[15.35]
420
[16.54]
420
[16.54]
DN 15, EN flange PN 40 DA 390
[15.35]
390
[15.35]
420
[16.54]
420
[16.54]
460
[18.11]
460
[18.11]
DN 15, EN flange PN 63 EF 390
[15.35]
390
[15.35]
420
[16.54]
420
[16.54]
460
[18.11]
460
[18.11]
DN 15, EN flange PN 100 DB 390
[15.35]
390
[15.35]
420
[16.54]
420
[16.54]
460
[18.11]
460
[18.11]
DN 15, EN flange PN 160 EG 390
[15.35]
390
[15.35]
420
[16.54]
420
[16.54]
460
[18.11]
DN 15, EN flange PN 250 EH 390
[15.35]
390
[15.35]
420
[16.54]
420
[16.54]
460
[18.11]
DN 15, EN flange PN 400 EI 390
[15.35]
390
[15.35]
420
[16.54]
420
[16.54]
460
[18.11]
DN 20, EN flange PN 40 DT 460
[18.11]
460
[18.11]
DN 25, EN flange PN 40 DC 390
[15.35]
390
[15.35]
420
[16.54]
420
[16.54]
460
[18.11]
460
[18.11]
625
[24.61]
DN 25, EN flange PN 63 EJ 390
[15.35]
390
[15.35]
420
[16.54]
420
[16.54]
460
[18.11]
460
[18.11]
625
[24.61]
DN 25, EN flange PN 100 DD 390
[15.35]
390
[15.35]
420
[16.54]
420
[16.54]
460
[18.11]
460
[18.11]
625
[24.61]
DN 25, EN flange PN 160 DW 390
[15.35]
390
[15.35]
420
[16.54]
420
[16.54]
460
[18.11]
DN 25, EN flange PN 160
Mat.: 2.4602 DW 625
[24.61]
DN 25, EN flange PN 250 DP 390
[15.35]
390
[15.35]
420
[16.54]
420
[16.54]
460
[18.11]
DN 25, EN flange PN 400 DV 390
[15.35]
390
[15.35]
460
[18.11]
DN 32, EN flange PN 40 DR 460
[18.11]
460
[18.11]
625
[24.61]
SLIP ON, PROCESS CONNECTION DIM. + FACING ACC. EN 1092-1 FORM B
INSTALLATION LENGTH IN MM [INCH]
20) Connections without installation length are not possible or need manufacturer release. Please contact the manufacturer.
Page 14 of 15
26
CLASSIC Series | TRICOR Coriolis Mass Flow Meters TRICOR Coriolis Mass Flow Meters | CLASSIC Series
27 23)Connections without installation length are not possible or need manufacturer release. Please contact the manufacturer.
Process connection23) Code TCM
0325
TCM
0650
TCM
1550
TCM
3100
TCM
5500
TCM
7900
TCM
028K
TCM
065K
TCM
230K
1⁄4” NPT female thread FJ 110
[4.33]
110
[4.33]
140
[5.51]
140
[5.51]
3⁄4” NPT female thread FL 110
[4.33]
110
[4.33]
140
[5.51]
140
[5.51]
460
[18.11]
460
[18.11]
1⁄2” NPT female thread FK 110
[4.33]
110
[4.33]
140
[5.51]
140
[5.51]
460
[18.11]
460
[18.11]
2” NPT female thread FQ 880
[34.65]
1⁄4” G. female thread FB 110
[4.33]
110
[4.33]
140
[5.51]
140
[5.51]
3⁄8” G, female thread FR 110
[4.33]
110
[4.33]
140
[5.51]
140
[5.51]
3⁄4” G, female thread FC 110
[4.33]
110
[4.33]
140
[5.51]
140
[5.51]
460
[18.11]
460
[18.11]
1⁄2” G, female thread FA 110
[4.33]
110
[4.33]
140
[5.51]
140
[5.51]
460
[18.11]
460
[18.11]
FEMALE THREAD
INSTALLATION LENGTH IN MM [INCH]
Process connection22) Code TCM
0325
TCM
0650
TCM
1550
TCM
3100
TCM
5500
TCM
7900
TCM
028K
TCM
065K
TCM
230K
DN125, EN flange PN 16 EX 915
[36.02]
DN125, EN flange PN 40 DN 915
[36.02]
DN125, EN flange PN 63 EY 915
[36.02]
DN125, EN flange PN 100 DO 915
[36.02]
DN150, EN flange PN 16 DI 915
[36.02]
DN150, EN flange PN 40 DX 915
[36.02]
SLIP ON, PROCESS CONNECTION DIM. + FACING ACC. EN 1092-1 FORM B
INSTALLATION LENGTH IN MM [INCH]
Process connection22) Code TCM
0325
TCM
0650
TCM
1550
TCM
3100
TCM
5500
TCM
7900
TCM
028K
TCM
065K
TCM
230K
DN 32, PN40 DIN 2635 –
1.4404 [AISI 316L] Type C Face VO 460
[18.11]
460
[18.11]
625
[24.61]
DN 32, PN64 DIN 2636 –
1.4404 [AISI 316L] Type E Face VP 460
[18.11]
460
[18.11]
625
[24.61]
DN 32, PN100 DIN 2637 –
1.4404 [AISI 316L] Type E Face VQ 460
[18.11]
460
[18.11]
625
[24.61]
EN FLANGE WELD NECK
INSTALLATION LENGTH IN MM [INCH]
Process connection22) Code TCM
0325
TCM
0650
TCM
1550
TCM
3100
TCM
5500
TCM
7900
TCM
028K
TCM
065K
TCM
230K
1⁄2” Triclamp TA 220
[8.66]
220
[8.66]
250
[9.84]
250
[9.84]
DN 25 Triclamp
PN 16 DIN 32676 TL 210
[8.27]
210
[8.27]
240
[9.45]
240
[9.45]
460
[18.11]
460
[18.11]
625
[24.61]
TRICLAMP
INSTALLATION LENGTH IN MM [INCH]
22) Connections without installation length are not possible or need manufacturer release. Please contact the manufacturer.
Page 15 of 15
www.tricorflow.com
Contact
N & S AMERICA
AW-Lake Company
2440 W. Corporate Preserve Dr. #600
Oak Creek WI 53154 | USA
+1 414 574 4300
CHINA
KEM flow technology (Beijing) Co., Ltd.
Rm. 906, Block C, Ruipu Office Bldg, No. 15
HongJunYingNan Road
Chaoyang District, Beijing 100012 | China
+86 10 84929567
REST OF WORLD
KEM Küppers Elektromechanik GmbH
Liebigstraße 5
85757 Karlsfeld | Germany
+49 8131 59391-100
ASIEA/PACIFIC, MIDDLE EAST
KEM Instruments SEA Pte. Ltd.
UEN: 201717792Z
1003 Bukit Merah Central #06-32
Singapur 159836
+65 6274 1130
Original KEM/AWL Dokument: TCM_E68_CLASSIC_D_EN_180720_E002 I Copyright KEM/AWL, Subject to change without notice